Expanding Targeted Instrumentation for Discovery Applications: Complement Reporter Ion Quantification with a Quadrupole-Ion Trap Instrument
Edward R. CruziD, Alex N. T. JohnsoniD, V. B. Pujari, Qi ZhangiD, Thao NguyeniD, Michael StadlmeieriD, Jessica WangiD, Cristina C. JacobiD, Graeme C. McAlisteriD, Philip M. RemesiD, Martin WühriD
Abstract
Proteomics workflows have traditionally been divided into discovery-based and targeted approaches, with instrumentation optimized specifically for each. Discovery experiments typically utilize high-resolution analyzers while targeted workflows rely on the sensitivity and specificity of triple quadrupole systems. Recently, a quadrupole-ion trap instrument (Stellar MS) demonstrated superior performance for targeted applications compared to conventional triple quadrupoles. In this study, we expand the capabilities of this platform to multiplexed shotgun proteomics using complement reporter ion quantification in an ion trap (iTMTproC). Benchmarking experiments with defined standards show that iTMTproC achieves quantification accuracy and interference reduction comparable to MultiNotch MS3 on the Orbitrap Fusion Lumos, a dedicated quadrupole-ion trap-Orbitrap tribrid instrument optimized for this purpose. Notably, iTMTproC quantifies slightly more proteins than MultiNotch MS3. We further validate this approach through a developmental time-series analysis of frog embryos, obtaining proteomic data nearly indistinguishable from MultiNotch MS3, with slightly increased protein quantification depth. These findings significantly extend the functionality of targeted instrumentation, underscoring the versatility of quadrupole-ion trap systems and providing cost-effective access to highly accurate, multiplexed quantitative shotgun proteomics.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 1
- FWCI
- 0.25
- Field percentile
- 38th percentile
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- TMTPro Complementary Ion Quantification Increases Plexing and Sensitivity for Accurate Multiplexed Proteomics at the MS2 Level
Alex N. T. Johnson, Michael Stadlmeier, Martin Wühr·Journal of Proteome ResearchPeer-reviewed·Apr 30, 2021
- Accurate, Sensitive, and Precise Multiplexed Proteomics using the Complement Reporter Ion Cluster
Matthew Sonnett, Eyan Yeung, Martin Wühr·Analytical ChemistryPeer-reviewed·Mar 9, 2018
- Enhancing Sensitivity in Targeted Single-Cell Proteomics by Coupling a Dual Ion Funnel Interface with Triple Quadrupole Mass Spectrometer
Sehong Min, Pearl Kwantwi-Barima, … Tujin Shi·Analytical ChemistryPeer-reviewed·Apr 2, 2026
- Super-resolution mass spectrometry enables rapid, accurate, and highly-multiplexed proteomics at the MS2-level
Anton N. Kozhinov, Alex N. T. Johnson, … Yury O. Tsybin·Analytical ChemistryPeer-reviewed·Feb 7, 2023
- A workflow for targeted proteomics assay development using a versatile linear ion trap
Ariana E. Shannon, Rachael Teodorescu, … Brian C. Searle·Nature CommunicationsPeer-reviewed·Apr 22, 2025
- High sensitivity quantitative proteomics using accumulated ion monitoring and automated multidimensional nano-flow chromatography
Paolo Cifani, Alex Kentsis·Molecular & Cellular ProteomicsPeer-reviewed·Aug 18, 2017