bioRxivBioengineeringPreprint
Bruch's Membrane Contributes to the Structural Integrity of the Human Eye
Royston K. Y. TaniD, Swati SharmaiD, Anita Sook Yee ChaniD, Candice Ee Hua HoiD, Fabian Albert BraeuiD, Jost Bruno JonasiD, Le HaniD, Xiaofei WangiD, Yinling Zhu, Hwa Liang LeoiD, Martin L. BuistiD, Tin AungiD, Shamira PereraiD, Michaël J. A. GirardiD
Abstract
PurposeTo investigate the contribution of the Bruchs membrane and sclera tissues to the overall structural integrity of the ocular wall. MethodsTwenty-three human globes were subjected to biomechanical testing. A piece of sclera measuring 5 x 5 mm was carefully removed at the nasal region, 2 mm away from the optic nerve head. The intraocular pressure was increased at approximately 1 mmHg/s until Bruchs membrane-uvea-retina-tissue layer (BMUR) ruptured. Next, strips of sclera and Bruchs membrane-choriocapillaris (BMC) complex were isolated from the superior fundus region. Uniaxial tension tests were performed at a strain rate of 0.01/s and sampling rate of 15 Hz. The tangent moduli of the BMC and sclera at 0.01, 0.02 and 0.03 strains were compared. ResultsThe rupture pressure of the BMUR was 98.1 {+/-} 21.4 mmHg. The tangent moduli of the BMC at 0.01, 0.02 and 0.03 strains were 2.96 {+/-} 1.44 MPa, 7.68 {+/-} 1.78 MPa and 9.43 {+/-} 2.11 MPa, respectively, and the tangent moduli of the sclera at 0.01, 0.02 and 0.03 strains were 1.09 {+/-} 0.80 MPa, 2.72 {+/-} 1.67 MPa and 5.69 {+/-} 3.27 MPa, respectively. ConclusionThe BMUR was able to sustain relatively high IOP before rupturing. The uniaxial tensile tests showed that the BMC tangent moduli were about 3 times of those of the sclera at strains of 0.01 and 0.02. Although the sclera is approximately 47 times thicker, the BMC is still likely to make a significant contribution (3.51% to 7.42% at strain <0.03) to the overall structural strength of the ocular wall.
- Citations
- 0
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- A Biphasic Approach for Characterizing Tensile, Compressive, and Hydraulic Properties of the Sclera
D. M. Brown, M. T. Pardue, C. R. Ethier·bioRxiv·May 21, 2020
- The Structural Layers of the Porcine Iris Exhibit Inherently Different Biomechanical Properties
R. K. Y. Tan, S. K. Panda, … M. J. A. Girard·bioRxiv·Dec 11, 2022
- Who bears the load? IOP-induced collagen fiber recruitment over the corneoscleral shell
T. Y. Foong, Y. Hua, … I. A. Sigal·Experimental Eye ResearchPeer-reviewed·May 1, 2023
- Interplay between intraocular and intracranial pressure effects on the optic nerve head in vivo
Z. Zhu, S. Waxman, … I. A. Sigal·bioRxiv·Dec 14, 2020
- Assessment of the Viscoelastic Mechanical Properties of the Porcine Optic Nerve Head using Micromechanical Testing and Finite Element Modeling
B. N. Safa, A. T. Read, C. R. Ethier·bioRxiv·Apr 16, 2021
- The Effects of Negative Periocular Pressure on Biomechanics of the Optic Nerve Head and Cornea: A Computational Modeling Study
B. N. Safa, A. Bleeker, … C. R. Ethier·bioRxiv·May 17, 2022