A Simulation Study on High Spatio-Temporal Resolution Acousto-Electrophysiological Neuroimaging
Ruben SchoetersiD, Thomas TarnaudiD, Luc MartensiD, Emmeric TangheiD
Abstract
Acousto-electrophysiological neuroimaging is a technique hypothesized to record electrophysiological activity of the brain with millimeter spatial and sub-millisecond temporal resolution. This improvement is obtained by tagging areas with focused ultrasound (fUS). Due to mechanical vibration with respect to the measuring electrodes, the electrical activity of the marked region will be modulated onto the ultrasonic frequency. The regions electrical activity can subsequently be retrieved via demodulation of the measured signal. In this study, the feasibility of this hypothesized technique is tested. This is done by calculating the forward electroencephalography (EEG) response under quasi-static assumptions. The head is simplified as a set of concentric spheres. Two sizes are evaluated representing human and mouse brains. Moreover, feasibility is assessed for wet and dry transcranial, and for cortically placed electrodes. The activity sources are modeled by dipoles, with their current intensity profile drawn from a power-law power spectral density. It is shown that mechanical vibration modulates the endogenous activity onto the ultrasonic frequency. The signal strength depends non-linearly on the alignment between dipole orientation, vibration direction and recording point. The strongest signal is measured when these three dependencies are perfectly aligned. The signal strengths are in the pV-range for a dipole moment of 5 nAm and ultrasonic pressures within FDA-limits. The endogenous activity can then be accurately reconstructed via demodulation. Two interference types are investigated: vibrational and static. Depending on the vibrational interference, it is shown that millimeter resolution signal detection is possible also for deep brain regions. Subsequently, successful demodulation depends on the static interference, that at MHz-range has to be sub-picovolt.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 1
- FWCI
- 0.08
- Field percentile
- 30th percentile
- Organism
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Non-invasive in vivo acoustoelectric neuromodulation and its contribution to ultrasound stimulation
Jean L. Rintoul, Christopher Butler, … Nir Grossman·Nature CommunicationsPeer-reviewed·Jun 17, 2026
- A window to the brain: ultrasound imaging of human neural activity through a permanent acoustic window
Claire Rabut, Sumner L. Norman, … Mikhail G. Shapiro·Science Translational MedicinePeer-reviewed·May 29, 2024
- High resolution ultrasonic neural modulation observedvia in vivo two-photon calcium imaging
- Acoustic frequency-dependent physical mechanism of sub-MHz ultrasound neurostimulation
- Ultrasound Produces Extensive Brain Activation via a Cochlear Pathway
Hongsun Guo, Mark Hamilton, … Hubert H. Lim·NeuronPeer-reviewed·May 24, 2018
- Activation Of Piezo1 But Not Nav1.2 Channels By Ultrasound at 43 MHz
Martin Loynaz Prieto, Kamyar Firouzi, … Merritt C. Maduke·Ultrasound in Medicine & BiologyPeer-reviewed·Jun 1, 2018