Journal of the American Society for Mass SpectrometryBiochemistryPeer-reviewed journal article
A universal buffer system for native LC-MS analysis of antibody-based therapeutics
Kent R. VosperiD, Bradley T. V. DavisiD, Jagandeep S. SarayaiD, Derek K. O’FlahertyiD, Algirdas VėlyvisiD, Siavash VahidiiD
Abstract
Liquid chromatography coupled to mass spectrometry (LC-MS) is a powerful analytical technique for analyzing biological macromolecules. A long-standing challenge has been applying LC-MS at physiological pH under native conditions using volatile buffers. The predominant "buffer" used, ammonium acetate (AmAc, pKa 4.75 for acetic acid and 9.25 for ammonium), does not offer sufficient buffering capacity in the physiological pH range of 7.0-7.4. To address this, we evaluated a set of fluorinated ethylamines, 2-fluoroethylamine (MFEA, pKa 8.9), 2,2-difluoroethylamine (DFEA, pKa 7.2), and 2,2,2-trifluoroethylamine (TFEA, pKa 5.5), that together provide buffering across the 4.5-9.8 pH range. We show that protein separations on strong cation- and anion-exchange resins in these volatile mobile phases perform comparably to traditional non-volatile buffers, with similar elution profiles and analyte elution ranking, albeit with slightly broader peaks. Using fully volatile gradients of pH or ionic strength, we chromatographically resolved charge variants of protein analytes such as mAbs and bovine serum albumin. For many of the eluting LC peaks, we obtained high-resolution mass spectra capable of resolving glycoforms of antibodies. Hydrophobic interaction chromatography (HIC) in volatile mobile phases preserved native separation order and further resolved drug-to-antibody ratio (DAR) species of the antibody-drug conjugate brentuximab-vedotin. For each chromatography modality we further compare innovator and biosimilar antibodies, demonstrating the reproducibility of results in the proposed volatile compounds. Together, our results establish fluorinated ethylamines, in combination with ammonium acetate, as a universal volatile buffer system for native LC-MS, broadly applicable across major chromatographic modalities while maintaining compatibility with mass spectrometry.
- Citations
- 2
- FWCI
- 3.04
- Field percentile
- top 10%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Polyacrylamide co-N,N'-methylene bisacrylamide monoliths for high peak capacity HILIC-HRMS of intact proteins at low trifluoroacetic acid content
M. Passamonti, C. de Roos, … A. Gargano·bioRxiv·Jul 14, 2021
- Benchmarking the Performance of a Commercial Electrostatic Linear Ion Trap (ELIT) Charge Detection Mass Spectrometer For Higher-Order Antibody Aggregate Analysis
Shang-Yin Wu, Xing-Miao Guo, … Wei‐Jie Fang·bioRxiv·Oct 15, 2026
- Improvements on Sample Preparation and Peptide Separation for Reduced Peptide Mapping Based Multi-Attribute Method analysis of Therapeutic Monoclonal Antibodies Using Lys-C Digestion
X. Li, B. Rawal, … D. Richardson·bioRxiv·Feb 28, 2022
- A novel LC system embeds analytes in pre-formed gradients for rapid, ultra-robust proteomics
N. Bache, P. E. Geyer, … M. Mann·bioRxiv·May 15, 2018
- Qualification of Identity, Quality-Attribute Monitoring and New Peak Detection in An Improved Multi-Attribute Method with Lys-C Digestion for Characterization and Quality Control of Therapeutic Monoclonal Antibodies
X. Li, N. A. Pierson, … D. D. Richardson·bioRxiv·May 1, 2022
- Fast-tracking native mass spectrometry: Skipping over buffer exchange
Alice Frederike Rosa Grün, Fatema-Aqila Said, … Charlotte Uetrecht·bioRxiv·Feb 22, 2025