Journal of Biomedical OpticsBiochemistryPeer-reviewed journal article
Indocyanine green excitation-emission matrix characterization: excitation-dependent emission shifts and application-specific spectra
Alberto J. RuiziD, Sophie A. Lyon, Ethan P. M. LaRochelleiD, Kimberley S. SamkoeiD
Abstract
SignificanceIndocyanine green (ICG) is the most widely used fluorophore in fluorescence-guided surgery (FGS), yet its spectral response depends on microenvironment, with implications for system design, inter-system comparisons, and phantom development. AimTo characterize ICG with excitation-emission matrices (EEMs) in the microenvironments of dimethyl sulfoxide (DMSO), bovine serum albumin (BSA) solutions, and 3D-printed (3DP) resin, and assess excitation-dependent emission, including red-edge excitation shifts (REES) and departures from Kashas rule of excitation-independent emission. ApproachEEMs and absorbance spectra were acquired with extracted excitation spectra, emission spectra, emission peaks, centroids, and integrated emission areas under the curve (AUCs). Concentration-dependent behavior was examined in DMSO, and albumin concentration dependence was assessed from 5-100 mg/mL. Data processing employed robust local regression to mitigate excitation scattering artifacts. ResultsICG in DMSO exhibited excitation-independent emission consistent with Kasha-Vavilov behavior. In contrast, ICG in BSA solution and 3DP resin displayed excitation-dependent emission with pronounced REES and additional non-linear departures from Kashas rule. To our knowledge, this represents the first documentation of REES and broader anti-Kasha effects for ICG or any FGS fluorophore. Within the excitation range most relevant to ICG-FGS ([~]760-805 nm), emission spectra of the BSA solution and 3DP resin overlapped closely, with similar AUC-based comparisons, suggesting that ICG in 3DP resin can serve as a suitable surrogate reference for albumin-bound ICG. ConclusionsThe EEM characterization shows that excitation-dependent behavior is a defining feature of ICG in biologically relevant environments, demonstrating that emission cannot be assumed to follow classical Kasha-Vavilov behavior. Reliable comparisons and imaging system design therefore require spectra acquired at defined excitation wavelengths with AUC integration within the emission detection band. Excitation-specific spectra from EEMs establish a consistent framework for inter-system comparisons and phantom standards, while the resulting datasets provide a practical reference for addressing excitation-dependent behavior in ICG sensing applications.
- Citations
- 0
- FWCI
- 0.00
- Field percentile
- top 43%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Protein enhanced NIR-IIb emission of indocyanine green for functional bioimaging
- Bright Near-infrared Anti-Stokes Fluorescence of ICG under Low Power CW Laser Excitation and its Applications in Bioimaging
- Shortwave Infrared Fluorescence Imaging with the Clinically Approved Near-Infrared Dye Indocyanine Green
J. A. Carr, D. Franke, … O. T. Bruns·bioRxiv·Apr 28, 2017
- Singlet-states-mediated highly efficient two-photon fluorescence in organic dyes
S Wang, Xiaoxiao Fan, … Jun Qian·bioRxiv·Jun 11, 2026
- Off-the-shelf NIR-I fluorophores as ready-to-use NIR-II probes: screening and in vivo validation
Marie‐Lynn Al‐Hawat, Marc K. Saba-El-Leil, Simon Matoori·bioRxiv·Aug 12, 2026
- Intravenous indocyanine green dye is insufficient for robust immune cell labelling in the human retina
O. H. Bell, E. Carreno, … C. J. Chu·bioRxiv·Nov 26, 2019