NMR in BiomedicineNeurosciencePeer-reviewed journal article
Gradient scheme optimization for PRESS-localized edited MRS using weighted pathway suppression
Gizeaddis Lamesgin SimegniD, Zahra ShamsiD, Saipavitra Murali‐ManohariD, Dunja SimičićiD, Abdelrahman Gamil GadiD, Yulu SongiD, Vivek Srikar YedavalliiD, Christopher W. Davies‐JenkinsiD, Aaron T. GudmundsoniD, Helge J. ZöllneriD, Georg OeltzschneriD, Richard A.E. EddeniD
Abstract
This study aimed to design and implement an optimized gradient scheme for PRESS-localized edited magnetic resonance spectroscopy (MRS) to enhance suppression of out-of-voxel (OOV) artifacts. These artifacts, which originate from insufficient crushing of unwanted coherence transfer pathways (CTPs), are particularly challenging in editing schemes for metabolites like gamma-aminobutyric acid and glutathione. To address this, a volume-based likelihood model was developed to guide gradient scheme optimization, prioritizing suppression of CTPs based on likelihood. A volume-based likelihood model for CTP weighting was integrated into a Dephasing optimization through coherence order pathway selection (DOTCOPS) gradient optimization. Using a genetic algorithm with a new dual-penalty cost function, gradient schemes were optimized to maximize pathway-specific suppression. Hardware and sequence constraints, maximum gradient amplitudes and delay durations respectively, informed the optimization. Validation of the optimized scheme was performed with simulations by calculating the k-space crushing efficiency analytically with k-space trajectory. and in vivo using an edited MRS sequence in three brain regions (posterior cingulate cortex PCC, thalamus, and medial prefrontal cortex (mPFC)), with particular focus on OOV artifact reduction and spectral quality improvements. A three-way Analysis of Variance was used to assess the significance level of OOV artifact reduction. The optimized gradient scheme demonstrated improved k-space crushing efficiency (by an average of 197%). OOV artifacts were reduced in all brain regions, particularly in highly OOV-susceptible regions (thalamus and mPFC). Improvements were most notable around 4.3 ppm with significant OOV artifact amplitude reductions (p < 0.001). By using a volume-based likelihood model for CTP prioritization, the optimized DOTCOPS scheme ensures robust and region-agnostic performance in reducing OOV artifacts.
- Citations
- 1
- FWCI
- 0.58
- Field percentile
- top 32%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Impact of gradient scheme and shimming on out-of-voxel echo artifacts in edited MRS
y. Song, H. J. Zöllner, … R. A. E. Edden·bioRxiv·Jul 10, 2022
- Identifying out-of-voxel echoes in edited MRS with phase cycle inversion
Zahra Shams, Abdelrahman Gad, … Richard A.E. Edden·Magnetic Resonance in MedicinePeer-reviewed·Dec 14, 2025
- MR Spectroscopy without Water Suppression using the Gradient Impulse Response Function
James B Bacon, Peter Jezzard, William T Clarke·Magnetic Resonance in MedicinePeer-reviewed·May 5, 2026
- Mapping glymphatic solute transportation through the perivascular space of hippocampal arterioles with 14 Tesla MRI
Xiaoqing Alice Zhou, Weitao Man, … Xin Yu·Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and ExhibitionPeer-reviewed·Nov 26, 2024
- Impacts of retrospective lipid suppression on metabolite quantification in preclinical proton MR spectroscopic imaging
Phan Tan Toi, Brayan Alves, … Cristina Cudalbu·bioRxiv·Sep 21, 2026
- Peripheral Nerve Stimulation Optimized Pulses for EPI (POPE) allows high-resolution fMRI
Laurentius Huber, Dominik Rattenbacher, … Rüdiger Stirnberg·bioRxiv·Jul 27, 2026