bioRxivPhysiology
Newly developed silicone airway stent (GINA stent): Mechanical characteristics and performance evaluation in pigs
H. S. Jung, G. Chae, J. H. Kim, S. Bae, C. Y. Park, S. Lim, S. E. Park, M. S. Jung, J. I. Park, Y. J. Lee, S. K. Kang, D. H. Kim, Y. Lee, T. Lee
Abstract
OBJECTIVESCentral airway obstruction (CAO) is caused by various malignant and benign processes. Surgery is a preferred option for CAO, but if not possible, bronchoscopic treatment could be performed. Recently, bronchoscopic treatments have been improved. Particularly in airway stents, new attempts are being made to overcome the existing shortcomings of stents (migration, mucostasis, and granulation tissue formation). We recently developed a new silicone airway stent (GINA stent). The GINA stent has anti-migration design, dynamic structure enabling reduction of stent cross-sectional area, and radiopaqueness. We sought to evaluate mechanical characteristics and performance of our novel GINA stent in a pig tracheal stenosis model. METHODSAll tests were performed by comparing GINA stent [outer diameter (OD, mm) 14, length (L, mm) 55] with Dumon stent (OD14L50). Mechanical tests were done using digital force gage to determine the anti-migration force, expansion force, and flexibility. Short-term (3 weeks) performance was evaluated after stent implantations [GINA (n = 4) vs. Dumon (n = 3)] in a pig model of tracheal stenosis. RESULTSMechanical properties outcomes for GINA vs. Dumon: anti-migration force [18.4 vs. 12.8 Newton (N)]; expansion force (11.9 vs. 14.5 N); flexibility (3.1 vs. 4.5 N). Short-term (3 weeks) GINA vs. Dumon performances: mucus retention (0/4 vs. 0/3); granulation tissue formation (0/4 vs. 0/3); migration (1/4 vs. 2/3). CONCLUSIONSGINA stent demonstrated better mechanical properties than Dumon stent with a stent performance not inferior to Dumon stent.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Rapid Establishment of Tracheal Stenosis in Pigs Using Endotracheal Tube Cuff Overpressure and Electrocautery
- Airway Diameter-Matched Injury Improves Severity and Reproducibility of Experimental Rabbit Tracheal Stenosis
Benjamin M. Laitman, Claire Victoria Ong, … Y Chen·bioRxiv·Jul 13, 2026
- Three-dimensional Printing of Customized Bioresorbable Airway Stents
N. Paunovic, Y. Bao, … J.-C. Leroux·bioRxiv·Sep 12, 2020
- Biomechanical Compatibility With Physiological Limb-Flexion Deformation Reduces Inflammation and Neointimal Hyperplasia After Peripheral Stenting
Alexey V. Kamenskiy, Barbara Batista de Oliveira, … Jason MacTaggart·bioRxiv·Oct 6, 2026
- NITINOL MATERIAL PROPERTIES OF 11 COMMERCIAL PERIPHERAL STENTS DETERMINED USING INVERSE COMPUTATIONAL ANALYSIS
Eric D. Anttila, Kaspars Maleckis, … Alexey V. Kamenskiy·bioRxiv·Nov 27, 2025
- Cell-cultured PDMS vascular model to allow placement of implant devices
Taku Okuno, Kazuyo Ito, … Daisuke Yoshino·BMC MethodsPeer-reviewed·May 11, 2026