BIO-PROTOCOLBiophysicsPeer-reviewed journal article
Time-resolved cryo-EM (TRCEM) sample preparation using a PDMS-based microfluidic chip assembly
Abstract
Time-resolved cryo-EM (TRCEM) makes it possible to provide structural and kinetic information on a reaction of biomolecules before the equilibrium is reached. Several TRCEM methods have been developed in the past to obtain key insights into the mechanism of action of molecules and molecular machines on the time scale of tens to hundreds of milliseconds, which is unattainable by the normal blotting method. Here we present our TRCEM setup utilizing a polydimethylsiloxane (PDMS)-based microfluidics chip assembly, comprising three components: a PDMS-based, internally SiO2-coated micromixer, a glass-capillary microreactor, and a PDMS-based microsprayer for depositing the reaction product onto the EM grid. As we have demonstrated in recent experiments, this setup is capable of addressing problems of severe sample adsorption and ineffective mixing of fluids, and leads to highly reproducible results in applications to the study of translation. As an example, we used our TRCEM sample preparation method to investigate the molecular mechanism of ribosome recycling mediated by High frequency of lysogenization X (HflX), which demonstrated the efficacy of the TRCEM device and its capability to yield biologically significant, reproducible information. This protocol has promise to provide structural and kinetic information on pre-equilibrium intermediates in the 10-1000 ms time range in applications to many other biological systems. Key featuresO_LIDesign and fabrication of high-performance splitting-and-recombination-based micromixer and planar microsprayer. C_LIO_LIProtocol for SiO2 coating on the PDMS surface and fabrication of the microfluidic chip assembly. C_LIO_LIPreparation of time-resolved cryo-EM sample in the time range of 10 - 1000 ms. C_LIO_LIData collection on EM grid covered with droplets from the microsprayer. C_LI
- Citations
- 6
- FWCI
- 1.96
- Field percentile
- top 17%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Time resolution in cryo-EM using a novel PDMS-based microfluidic chip assembly and its application to the study of HflX-mediated ribosome recycling
S. Bhattacharjee, J. Frank, X. Feng·CellPeer-reviewed·Feb 1, 2024
- Visual Biochemistry: modular microfluidics enables kinetic insight from time-resolved cryo-EM
M.-E. Maeots, B. Lee, … R. I. Enchev·Nature CommunicationsPeer-reviewed·Jul 10, 2020
- Time-resolved cryo-EM using a combination of droplet microfluidics with on-demand jetting
S. TORINO, M. Dhurandhar, … R. G. Efremov·bioRxiv·Oct 21, 2022
- Time-Resolved Cryo-EM Specimen Preparation with Single Millisecond Precision
A. Montano Romero, C. Bonin, E. C. Twomey·bioRxiv·Aug 24, 2023
- Mix-it-up: Accessible time-resolved cryo-EM on the millisecond timescale
Lauren Alexandrescu, William Lessin, Gabriel C. Lander·IUCrJPeer-reviewed·Oct 21, 2025
- Microsecond melting and revitrification of cryo samples with a correlative light-electron microscopy approach
G. Bongiovanni, O. F. Harder, … U. J. Lorenz·bioRxiv·Sep 14, 2022