henhaobio
Sign in

BIO-PROTOCOLBiophysicsPeer-reviewed journal article

Time-resolved cryo-EM (TRCEM) sample preparation using a PDMS-based microfluidic chip assembly

Xiangsong FengiD, Joachim FrankiD

PDFDOIPreprint

Abstract

Time-resolved cryo-EM (TRCEM) makes it possible to provide structural and kinetic information on a reaction of biomolecules before the equilibrium is reached. Several TRCEM methods have been developed in the past to obtain key insights into the mechanism of action of molecules and molecular machines on the time scale of tens to hundreds of milliseconds, which is unattainable by the normal blotting method. Here we present our TRCEM setup utilizing a polydimethylsiloxane (PDMS)-based microfluidics chip assembly, comprising three components: a PDMS-based, internally SiO2-coated micromixer, a glass-capillary microreactor, and a PDMS-based microsprayer for depositing the reaction product onto the EM grid. As we have demonstrated in recent experiments, this setup is capable of addressing problems of severe sample adsorption and ineffective mixing of fluids, and leads to highly reproducible results in applications to the study of translation. As an example, we used our TRCEM sample preparation method to investigate the molecular mechanism of ribosome recycling mediated by High frequency of lysogenization X (HflX), which demonstrated the efficacy of the TRCEM device and its capability to yield biologically significant, reproducible information. This protocol has promise to provide structural and kinetic information on pre-equilibrium intermediates in the 10-1000 ms time range in applications to many other biological systems. Key featuresO_LIDesign and fabrication of high-performance splitting-and-recombination-based micromixer and planar microsprayer. C_LIO_LIProtocol for SiO2 coating on the PDMS surface and fabrication of the microfluidic chip assembly. C_LIO_LIPreparation of time-resolved cryo-EM sample in the time range of 10 - 1000 ms. C_LIO_LIData collection on EM grid covered with droplets from the microsprayer. C_LI

Citations
6
FWCI
1.96
Field percentile
top 17%

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.

Sign in to file a reproducibility report.

Similarity Map
SelectedSame fieldCross-field
THISBhattacharj '24Maeots '20TORINO '22Romero '23Alexandresc '25Bongiovanni '22
84% semantic matchBiophysics
S. Bhattacharjee, J. Frank, X. Feng·Cell·Feb 1, 2024