bioRxivBioengineering
Interactive computational and experimental approaches improve the sensitivity of periplasmic binding protein-based nicotine biosensors for measurements in biofluids
N. Haloi, S. Huang, A. L. Nichols, E. J. Fine, N. J. Friesenhahn, C. B. Marotta, D. A. Dougherty, E. Lindahl, R. J. Howard, S. L. Mayo, H. A. Lester
Abstract
We developed fluorescent protein sensors for nicotine with improved sensitivity. For iNicSnFR12 at pH 7.4, the proportionality constant for {Delta}F/F0 vs [nicotine] ({delta}-slope, 2.7 M-1) is 6.1-fold higher than the previously reported iNicSnFR3a. The activated state of iNicSnFR12 has a fluorescence quantum yield of at least 0.6. We measured similar dose-response relations for the nicotine-induced absorbance increase and fluorescence increase, suggesting that the absorbance increase leads to the fluorescence increase via the previously described nicotine-induced conformational change, the "candle snuffer" mechanism. Molecular dynamics (MD) simulations identified a binding pose for nicotine, previously indeterminate from experimental data. MD simulations also showed that Helix 4 of the periplasmic binding protein (PBP) domain appears tilted in iNicSnFR12 relative to iNicSnFR3a, likely altering allosteric network(s) that link the ligand binding site to the fluorophore. In thermal melt experiments, nicotine stabilized the PBP of the tested iNicSnFR variants. iNicSnFR12 resolved nicotine in diluted mouse and human serum at 100 nM, the peak [nicotine] that occurs during smoking or vaping, and possibly at the decreasing levels during intervals between sessions. NicSnFR12 was also partially activated by unidentified endogenous ligand(s) in biofluids. Improved iNicSnFR12 variants could become the molecular sensors in continuous nicotine monitors for animal and human biofluids.
- organism: mouse
- organism: human
- assay: fluorescence / live-cell microscopy
- research focus: cell type annotation
- research focus: differential expression
- approach: experimental assay
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Fluorescence Activation Mechanism and Imaging of Drug Permeation with New Sensors for Smoking-Cessation Ligands
A. L. Nichols, Z. Blumenfeld, … H. A. Lester·bioRxiv·Oct 4, 2021
- Hydrogel encapsulation of a designed fluorescent protein biosensor for continuous measurements of sub-100 nanomolar nicotine
Aaron L. Nichols, Christopher B. Marotta, … Henry A. Lester·bioRxiv·Dec 2, 2024
- Three Mutations Convert the Selectivity of a Protein Sensor From Nicotinic Agonists to S-Methadone For Use in Cells, Organelles, and Biofluids
A. K. Muthusamy, C. H. Kim, … H. A. Lester·bioRxiv·Feb 24, 2022
- Wearable sweat nicotine biosensor based on a nicotineoxidoreductase and its natural electron acceptor
Zhehao Zhang, Abdurrahman Addokhi, … James E. Galagan·bioRxiv·Oct 31, 2025
- Using Latent Chemical Recognition in an Evolved Periplasmic Binding Protein Family to Diversify Biosensors
Eryney Marrogi, Aaron L. Nichols, … Anand K. Muthusamy·bioRxiv·Aug 4, 2026
- A computationally designed fluorescent biosensor for D-serine
V. Vongsouthi, J. H. Whitfield, … C. J. Jackson·bioRxiv·Aug 18, 2020