Effect of terminal phosphate groups on collisional dissociation of RNA oligonucleotide anions
Mei-Qing Zuo, Ge SongiD, Jishuai ZhangiD, Meng‐Qiu DongiD, Rui‐Xiang SuniD
Abstract
An increasing need of mass spectrometric analysis of RNA molecules calls for a better understanding of their gas-phase fragmentation behaviors. In this study, we investigated the effect of terminal phosphate groups on the fragmentation spectra of RNA oligonucleotides (oligos) using high-resolution mass spectrometry (MS). Negative-ion mode collision-induced dissociation (CID) and higher-energy collisional dissociation (HCD) were carried out on RNA oligos containing a terminal phosphate group on either or both ends, or neither. We find that terminal phosphate groups affect the fragmentation behavior of RNA oligos in a way that depends on the precursor charge state and the oligo length. Specifically, for precursor ions of RNA oligos of the same sequence, those with 5- or 3-phosphate, or both, have a higher charge state distribution and lose upon CID or HCD the phosphate group(s) in the form of a neutral (H3PO4 or HPO3) or an anion ([H2PO4]- or [PO3]-). Such neutral or charged loss is most conspicuous for precursor ions of an intermediate charge state, e.g. 3- for 4-nt oligos or 4- and 5- for 8-nt oligos. This decreases the intensity of sequencing ions (a-, a-B, b-, c-, d-, w-, x-, y-, z-ions), hence unfavorable for sequencing by CID or HCD. Removal of terminal phosphate groups by calf intestinal alkaline phosphatase improved MS analysis of RNA oligos. Additionally, the intensity of a fragment ion at m/z 158.925, which we have identified as a dehydrated pyrophosphate anion ([HP2O6]-), is markedly increased by the presence of a terminal phosphate group. These findings expand the knowledge base necessary for software development for MS analysis of RNA.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 4
- FWCI
- 0.50
- Field percentile
- 49th percentile
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Charge-State-Dependent Collision-Induced Dissociation Behaviors of RNA Oligonucleotides via High-Resolution Mass Spectrometry
Rui‐Xiang Sun, Mei-Qing Zuo, … Meng‐Qiu Dong·Journal of the American Society for Mass SpectrometryPeer-reviewed·Jul 18, 2023
- Ion-Pair-Free Nanoflow HILIC-MS With RNase Benchmarking for Native RNA
Ying Qi, Chengkang Li, … Stefanie Kaiser·bioRxiv·Nov 18, 2025
- Enzymatic Ligation Strategy to Enhance Electrospray Ionization Efficiency and Liquid Chromatography-Mass Spectrometry of DNA and RNA Oligonucleotides
Max D. Sharin, Nina J. Fitzgerald, … Kevin D. Clark·Analytical ChemistryPeer-reviewed·Sep 14, 2026
- LC-MS analysis of RNA through hydrogen bonding of alkylamines
Robert L. Ross, Michael J. Sutton, … Michael G. Bartlett·bioRxiv·Mar 18, 2025
- Ion-Pair-Free Capillary HILIC-MS for Sensitive Nucleic Acid Analysis and RNA Modification Mapping
Junzhou Wu, Rana Togay, … Peter C. Dedon·bioRxiv·Aug 20, 2026
- RNabel-A Standalone Software Tool for Annotating Tandem Mass Spectra of Modified Ribonucleic Acids
Ge Song, Yi-Jie Nathan Du, … Meng‐Qiu Dong·Analytical ChemistryPeer-reviewed·Sep 28, 2026