SensorsNeurosciencePeer-reviewed journal article
Biplanar nulling coil system for OPM-MEG using printed circuit boards
Mainak JasiD, John Kamataris, Teppei MatsubaraiD, Chunling Dong, Gabriel Motta, Abbas SohrabpouriD, Seppo P. AhlforsiD, Matti HämäläineniD, Yoshio C OkadaiD, Padmavathi SundaramiD
Abstract
Optically pumped magnetometers (OPMs) are a promising sensor technology for non-invasive measurement of human electrophysiological signals, in particular the magnetoencephalogram (MEG). OPMs do not need cryogenic cooling and can be placed conformal to the subjects scalp, thus greatly reducing the sensor-to-source distance and improving signal sensitivity. OPMs, however, require near-zero background magnetic field to achieve linearity and minimize signal distortion. Prior work has proposed the use of biplanar field nulling coils to remove the uniform and gradient components of the background magnetic field. Biplanar coils have been expensive to construct, involving tedious error-prone manual winding of over 1000 m of copper wire. In this work, we designed and fabricated background field nulling coils (three uniform and three gradient components) on two-layer Printed Circuit Boards (PCBs). We used an open-source software (bfieldtools) to determine the current loops needed to produce the target magnetic field in a 50-cm-diameter spherical volume. We developed a software-based approach to connect the discrete current loops into a continuous conducting path traversing the two layers of the PCB. For ease of manufacture, the designed (1.5 x 1.5 m2) coils were cut along the symmetry axis and printed as pairs of 1.5 x 0.75 m2 PCBs (2 oz Cu), soldered together and mounted on a sliding aluminum frame. The efficiency of the coils (1.3 - 7.1 nT/mA) was similar or higher than previously reported in the literature. We mapped the field inside the target region after field nulling inside our single-layer shielded room and were able to reduce the largest component of the background field from 21 to 2 nT. Using our nulling coil system, we were able to operate OPMs in a lightly shielded room (background field varying from 6.5 to 108 nT in the floor-to-ceiling direction) to record somatosensory evoked fields (SEFs) comparable to those measured using SQUID-based MEG in a 3-layer shielded room. We disseminate the software and hardware as an open-source package opmcoils. This work will facilitate access to more affordable field nulling coils for OPM-MEG and help to realize the potential of OPM-MEG as an accessible sensor technology for use in human neuroscience.
- Citations
- 3
- FWCI
- 1.10
- Field percentile
- top 27%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- On-scalp MEG system utilizing an actively shielded array of optically-pumped magnetometers
Joonas Iivanainen, Rasmus Zetter, … Lauri T. Parkkonen·NeuroImagePeer-reviewed·Mar 15, 2019
- Using OPM-MEG in contrasting magnetic environments
Ryan M. Hill, Jasen Devasagayam, … Matthew J. Brookes·NeuroImagePeer-reviewed·Mar 9, 2022
- Measuring MEG closer to the brain: Performance of on-scalp sensor arrays
Joonas Iivanainen, Matti Stenroos, Lauri T. Parkkonen·NeuroImagePeer-reviewed·Dec 19, 2016
- A Novel, Robust, and Portable Platform for Magnetoencephalography using Optically Pumped Magnetometers
Holly Schofield, Ryan M. Hill, … Matthew J. Brookes·Imaging NeurosciencePeer-reviewed·Jan 1, 2024
- Magnetic Field Mapping and Correction for Moving OP-MEG
Stephanie Mellor, Tim M. Tierney, … Gareth Robert Barnes·IEEE Transactions on Biomedical EngineeringPeer-reviewed·Jul 29, 2021
- Detection of the 40-Hz Auditory Steady-state Response with Optically Pumped Magnetometers
Kyung‐min An, Jeong Hyun Shim, … Kiwoong Kim·Scientific ReportsPeer-reviewed·Oct 26, 2022