Assessing the Impact of Valve Sizing and Orientation on Bioprosthetic Pulmonary Valve Hemodynamics Using In Vitro 4D-Flow MRI
Nicole SchiavoneiD, Priya J. NairiD, Christopher J. ElkinsiD, Doff B. McElhinneyiD, Daniel B. EnnisiD, John K. EatoniD, Alison Lesley MarsdeniD
Abstract
PurposePulmonary valve replacement (PVR) using bioprosthetic valves is a common procedure performed in patients with repaired Tetralogy of Fallot and other conditions, but these valves frequently become dysfunctional within 15 years of implantation. Since PVR is often performed in adolescence, valves are typically oversized to account for somatic growth. However, the contribution of oversizing to early valve failure are not clearly understood. The purpose of this study was to explore the impact of valve sizing and orientation on local hemodynamics and valve performance. MethodsDifferent valve sizes were represented by changing the cardiac output through a 25 mm bioprosthetic valve implanted in an idealized 3D-printed model of the right ventricular outflow tract (RVOT). The local hemodynamics at three valve sizes and two valve orientations were assessed using 4D-Flow MRI and high-speed camera imaging. ResultsNoticeable differences in jet asymmetry, the amount of recirculation, leaflet opening patterns, as well as the size and location of reversed flow regions were observed with varying valve sizes. Rotation of the valve resulted in drastic differences in reversed flow regions, but not forward flow. ConclusionFlow features observed in the oversized valve in this study have previously been correlated with calcification, hemolysis, and leaflet fatigue. Therefore, valve oversizing can negatively impact local hemodynamics and leaflet performance.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 3
- FWCI
- 0.84
- Field percentile
- top 22%
- Assay
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Parametric Engineering of Atrioventricular Living Valve Transplants
Paul R. Kaneelil, Katrina J. Hon, … Sitaram M. Emani·bioRxiv·Jun 18, 2026
- The Tricuspid Valve Maladapts in a Pulmonary Hypertension Rat Model
Chien-Yu Lin, Bogusław Gawęda, … Manuel K. Rausch·bioRxiv·Jul 12, 2026
- A Patient-Specific Model of Transcatheter Valve Replacement in aBicuspid Heart Valve
O. M. McGee, A. McNamara, L. M. McNamara·bioRxiv·Mar 5, 2021
- Biomimetic biaxial mechanical properties enhance hemodynamic performance and prevent adverse tissue remodelling in tissue-engineered heart valves
Bahram Mirani, Sean O. Mathew, … Craig A. Simmons·bioRxiv·Mar 2, 2025
- Dissecting contributions of pulmonary arterial remodeling to right ventricular afterload in pulmonary hypertension
Sunder Neelakantan, Emilio A. Mendiola, … Reza Avazmohammadi·Bioengineering & Translational MedicinePeer-reviewed·Jun 26, 2025
- Three-Dimensional Fluid-Structure Interaction Reveals Trade-offs Among Oxygen Delivery, Shear, and Washout in Pediatric Roller-Pump Cardiopulmonary Bypass
Yunpeng Tu, Yi‐Ting Yeh, … Christina L. Greene·bioRxiv·Oct 28, 2026