Lab on a ChipBioengineeringPeer-reviewed journal article
Liquid plug propagation in computer-controlled microfluidic airway-on-a-chip with semi-circular microchannels
H. Viola, V. Vasani, K. Washington, J. H. Lee, C. Selva, A. Li, C. J. Llorente, Y. Murayama, J. B. Grotberg, F. Romano, S. Takayama
Abstract
This paper introduces a two-inlet, one-outlet lung-on-a-chip device with semi-circular cross-section microchannels and computer-controlled fluidic switching that enables a broader systematic investigation of liquid plug dynamics in a manner relevant to the distal airways. A leak-proof bonding protocol for micro-milled devices facilitates channel bonding and culture of confluent primary small airway epithelial cells. Production of liquid plugs with computer-controlled inlet channel valving and just one outlet allows more stable long-term plug generation and propagation compared to previous designs. The system also captures both plug speed and length as well as pressure drop concurrently. In one demonstration, the system reproducibly generates surfactant-containing liquid plugs, a challenging process due to lower surface tension that makes the plug formation less stable. The addition of surfactant decreases the pressure required to initiate plug propagation, a potentially significant effect in diseases where surfactant in the airways is absent or dysfunctional. Next, the device recapitulates the effect of increasing fluid viscosity, a challenging analysis due to higher resistance of viscous fluids that makes plug formation and propagation more difficult particularly in airway-relevant length scales. Experimental results show that increased fluid viscosity decreases plug propagation speed for a given air flow rate. These findings are supplemented by computational modeling of viscous plug propagation that demonstrate increased plug propagation time, increased maximum wall shear stress, and greater pressure differentials in more viscous conditions of plug propagation. These results match physiology as mucus viscosity is increased in various obstructive lung diseases where it is known that respiratory mechanics can be compromised due to mucus plugging of the distal airways. Finally, experiments evaluate the effect of channel geometry on primary human small airway epithelial cell injury in this lung-on-a-chip. There is more injury in the middle of the channel relative to the edges highlighting the role of channel shape, a physiologically relevant parameter as airway cross-sectional geometry can also be non-circular. In sum, this paper describes a system that pushes the device limits with regards to the types of liquid plugs that can be stably generated for studies of distal airway fluid mechanical injury.
- organism: human
- assay: imaging
- research focus: cell type annotation
- research focus: cell-cell communication
- approach: experimental assay
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- An Adhesive Based Fabrication Technique for Culture of Lung Airway Epithelial Cells with Applications in Microfluidics and Lung on a Chip
N. Tiessen, M. Dabaghi, … J. Hirota·bioRxiv·Nov 19, 2020
- Collagen Tubular Airway-on-Chip for Extended Epithelial Culture andInvestigation of Ventilation Dynamics
W. Gao, K. R. Kanagarajah, … A. Guenther·bioRxiv·Oct 5, 2023
- Airway smooth muscle--on-a-chip: a microfluidic approach to study alveolar smooth muscle remodelling
Amir Suhail, Joseph Xavier, … Jorge Bernardino de la Serna·bioRxiv·Mar 13, 2025
- Cilia dynamics creates a dynamic barrier to penetration of the periciliary layer in human airway epithelia
Erika Causa, Debasish Das, … Pietro Cicuta·Proceedings of the National Academy of SciencesPeer-reviewed·Jul 11, 2025
- Luminal Flow Actuation Generates Coupled Shear and Strain in a Microvessel-on-Chip
C. A. Dessalles, C. Ramon-Lozano, … A. I. Barakat·bioRxiv·Apr 10, 2021
- Modelling cigarette smoke-induced lung vascular dysfunction using an alveolus-on-chip
Abilash Ravi, Tarek Gensheimer, … Anne M. van der Does·Materials Today BioPeer-reviewed·Jul 6, 2026