Effective Ultrasonic Stimulation in Human Peripheral Nervous System
Abstract
ObjectiveLow-intensity ultrasound can stimulate excitable cells in a noninvasive and targeted manner, but which parameters are effective has remained elusive. This question has been difficult to answer because differences in transducers and parameters--frequency in particular--lead to profound differences in the stimulated tissue volumes. The objective of this study is to control for these differences and evaluate which ultrasound parameters are effective in stimulating excitable cells. MethodsHere, we stimulated the human peripheral nervous system using a single transducer operating in a range of frequencies, and matched the stimulated volumes with an acoustic aperture. ResultsWe found that low frequencies (300 kHz) are substantially more effective in generating tactile and nociceptive responses in humans compared to high frequencies (900 kHz). The strong effect of ultrasound frequency was observed for all pressures tested, for continuous and pulsed stimuli, and for tactile and nociceptive responses. ConclusionThis prominent effect may be explained by a mechanical force associated with ultrasound. The effect is not due to heating, which would be weaker at the low frequency. SignificanceThis controlled study reveals that ultrasonic stimulation of excitable cells is stronger at lower frequencies, which guides the choice of transducer hardware for effective ultrasonic stimulation of the peripheral nervous system in humans.
02 /Specification & Classification
Click any tag to browse matching papers- Organism
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Acoustic frequency-dependent physical mechanism of sub-MHz ultrasound neurostimulation
- Physical mechanisms of ultrasonic neurostimulation of the retina
Mike D. Menz, Patrick Peiyong Ye, … Stephen A. Baccus·bioRxiv·Dec 11, 2017
- Modulating Peripheral Neural Activity: Prolonged Low-Intensity Ultrasound for Controlled Excitation and Suppression in Rat Sciatic Nerve
Heba M. Badawe, Pierre D. Mourad, Massoud L. Khraiche·Scientific ReportsPeer-reviewed·Oct 1, 2025
- Ultrasound pulse repetition frequency preferentially activates different neuron populations independent of cell type
Jack Sherman, Emma Bortz, … Xue Han·Journal of Neural EngineeringPeer-reviewed·Aug 23, 2024
- Activation Of Piezo1 But Not Nav1.2 Channels By Ultrasound at 43 MHz
Martin Loynaz Prieto, Kamyar Firouzi, … Merritt C. Maduke·Ultrasound in Medicine & BiologyPeer-reviewed·Jun 1, 2018
- Focused ultrasound excites neurons via mechanosensitive calcium accumulation and ion channel amplification
Sangjin Yoo, David Reza Mittelstein, … Mikhail G. Shapiro·bioRxiv·May 19, 2020