How to design 1000-plex mass tags using the differential mass defect
Harrison SpechtiD, Kevin A. McDonnelliD, Daniel GeiszleriD, Michael P. AgiusiD
Abstract
Multiplexing samples in mass spectrometry-based proteomics has long been accomplished by iso-topologues of small molecules. These chemically-identical "mass tags" conjugate to peptides to encode samples with different mass offsets for parallel analysis. The current state-of-the-art for multiplexing with non-isobaric mass tags was recently improved from 3-plex to 9-plex, but what is the largest plex size that can be reasonably achieved with current technology? A full answer to this question requires evaluating current mass spectrometry hardware, facets of which have been well-investigated by others. However, it may be underappreciated that multiplexing 1000s of samples with mass tags does not actually require 1000s of isotopes, or 1000s of synthesis steps to create. Non-intuitively, high plex mass tags can require relatively few different isotopes. The focus of this exposition is to characterize the potential of the differential mass defect to create tens to over a thousand isotopologues of small molecules and how careful combinations of these small molecules can combinatorially scale the plex size to minimize synthetic steps. Importantly, we show that plex sizes in the hundreds, an order of magnitude greater than state-of-the-art, are achievable using molecules comparable in size to existing commercial tags, and that going beyond hundreds may require larger molecules. Approaches to achieve high-plex proteomics will almost certainly require using the differential mass defect, so we hope this exposition serves to accelerate progress in reagent development to achieve high plex proteomics.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 0
- FWCI
- 0.00
- Field percentile
- top 36%
- Assay
- Research Focus
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- PSMtags improve peptide sequencing and throughput in sensitive proteomics
Harrison Specht, Sarah N. Sipe, … Nikolai Slavov·bioRxiv·May 22, 2025
- timePlex: Increasing mass spectrometry throughput using time-encoded sample multiplexing
Jason Derks, Kevin A. McDonnell, … Nikolai Slavov·bioRxiv·May 22, 2025
- Limits for resolving tandem mass tag reporter ions with identical integer mass using phase constrained spectrum deconvolution
C. D. Kelstrup, K. Aizikov, … J. V. Olsen·bioRxiv·May 28, 2018
- Accurate, Sensitive, and Precise Multiplexed Proteomics using the Complement Reporter Ion Cluster
Matthew Sonnett, Eyan Yeung, Martin Wühr·Analytical ChemistryPeer-reviewed·Mar 9, 2018
- TMTPro Complementary Ion Quantification Increases Plexing and Sensitivity for Accurate Multiplexed Proteomics at the MS2 Level
Alex N. T. Johnson, Michael Stadlmeier, Martin Wühr·Journal of Proteome ResearchPeer-reviewed·Apr 30, 2021
- EASI-tag enables accurate multiplexed and interference-free MS2-based proteome quantification
S. Virreira Winter, F. Meier, … F. Meissner·bioRxiv·Nov 27, 2017