Dosimetric Characterization and Workflow Optimization of the FLASH-SARRP for Reliable Preclinical Radiobiological Studies

Michèle KnoliD, Patrik Gonçalves Jorge, L. L. KunziD, Pierre KoryskoiD, Benoît PetitiD, André‐Dante DurhamiD, Marie‐Catherine VozeniniD, Pelagia Pauletta TsoutsouiD, Nikolaos KoutsouvelisiD, Julie LascaudiD

PDFDOI
Citations
0

Abstract

Objective: The reliable use of preclinical small-animal irradiators requires dosimetric characterization and quality assurance (QA) protocols. This study aimed to characterize the FLASH-SARRP, a dual-tube small-animal X-ray irradiator capable of ultra-high dose-rate (UHDR) delivery, as well as to establish and validate a practical QA workflow that improves dose reproducibility for preclinical FLASH experiments. Approach: A combined dosimetric approach using Gafchromic films for spatial dose assessment and a plastic scintillating fiber for real-time temporal monitoring, was used to evaluate beam characteristics. Custom 3D-printed spacers were designed to ensure reproducible experimental configurations. The temporal pulse structure of the two X-ray tubes and their synchronization during simultaneous irradiation were investigated using scintillating fiber measurements. Based on the findings of the two dosimeters, a QA workflow was implemented and validated, which uses a cross-calibration between the Gafchromic film and the scintillating fiber in the experimental setup, followed by pre-irradiation verification with the fiber to compensate for day-to-day output variations. Main results: Simultaneous irradiation of both X-ray tubes achieved dose-rates of approximately 80 Gy/s inside a homogeneous irradiation field suitable for small-animal studies. Temporal measurements revealed an average delay of 10 ms in between the two X-ray tubes, resulting in temporal dose-rate heterogeneity throughout the delivery of the dose. Additionally, a substantial inter-session variability of approximately 11% was found, whereas the intra-session variability was relatively low around ~4%. Implementation of the proposed QA workflow reduced the inter-session variability to around 5%, approaching the intrinsic intra-session variability of the machine. Significance: This work highlights the importance of temporal dosimetry for preclinical FLASH studies, as a measurable desynchronization between the two X-ray tubes was identified, generating temporal dose-rate heterogeneity that would not be detected by integrated dose measurements alone. The proposed QA framework improves reproducibility and provides a practical approach for reliable preclinical investigations.

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.

Sign in to file a reproducibility report.

Similarity Map
SelectedSame fieldCross-field
THISLin '25Drayson '24Zazpe '24Giaccaglia '26Gao '20Medina '26
63% semantic matchCancer Biology
Binwei Lin, Huan Du, Yiwei Yang+20 more·International Journal of Radiation Oncology*Biology*Physics·Oct 13, 2025· 10 citations