Isotropic, aberration-corrected light sheet microscopy for rapid high-resolution imaging of cleared tissue
Mostafa AakhteiD, G.A. MülleriD, Lennart RoosiD, Joe Li, Torben GöpeliD, Kurt R. WeissiD, Aleyna M. Diniz, Jan WenzeliD, Markus SchwaningeriD, Tobias MoseriD, Jan HuiskeniD
Abstract
Light sheet microscopy is the ideal technique for multiscale imaging of large and cleared tissues, and it is desirable to achieve the highest possible isotropic resolution across the entire sample. However, isotropic resolution for a centimeter-sized sample has only been achieved with slow and often aberrated, axially scanned light sheets, resulting in a low resolution of several micrometers. Here, we introduce a compact, high-speed light sheet fluorescence microscope with isotropic sub-micron resolution optimized for cleared tissue. We introduce three major opto-mechanical innovations using off-the-shelf optics to achieve an isotropic resolution of 850 nm across samples up to 1 cm3 and refractive indices ranging from 1.33 to 1.56, using mechanical tiling with a field of view of 800 {micro}m x 800 {micro}m. We show that combining an air objective and a meniscus lens achieves an axially swept light sheet with sub-micron diffraction-limited resolution and aberration correction. The effective field of view is increased 2-fold by correcting the field curvature of the light sheet with a concave mirror in the remote focusing unit. Furthermore, the imaging speed is enhanced 10-fold by adapting the light sheets motion with a closed-loop feedback, reaching 100 frames per second while maintaining isotropic resolution across the large field of view. Finally, we showcase the performance of our light sheet system for imaging from subcellular up to centimeter scale in cleared zebrafish, mouse cochlea, and mouse brain using various clearing methods.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 12
- FWCI
- 4.56
- Field percentile
- top 4%
- Organism
- Assay
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Light-sheet microscopy with isotropic, sub-micron resolution and solvent-independent large-scale imaging
Tonmoy Chakraborty, Meghan Driscoll, … Reto Fiolka·bioRxiv·Apr 11, 2019
- Mechanically Sheared Axially Swept Light-Sheet Microscopy
Jinlong Lin, Dushyant Mehra, … Kevin M. Dean·Biomedical Optics ExpressPeer-reviewed·Jul 26, 2024
- Curved light sheet microscopy for centimeter-scale cleared tissues imaging
Lijuan Tang, Jiayu Wang, … Jianglai Wu·Nature PhotonicsPeer-reviewed·Apr 11, 2025
- Open-top axially swept light sheet microscopy
Bumju Kim, Myeongsu Na, … Ki Hean Kim·Biomedical Optics ExpressPeer-reviewed·Mar 21, 2021
- Light-sheet mesoscopy with the Mesolens provides fast sub-cellular resolution imaging throughout large tissue volumes.
E. Battistella, J. Schniete, … G. McConnell·bioRxiv·Mar 22, 2022
- High-Resolution, Large Imaging Volume, and Multi-View Single Objective Light-Sheet Microscopy
Bin Yang, Merlin Lange, … Löıc A. Royer·Nature MethodsPeer-reviewed·Mar 21, 2022