henhaobio
Sign in

medRxivGenetic & Genomic MedicinePreprint

Development and fit for purpose validation of a quantitative LC-MS/MS method for heparan sulfate in cerebrospinal fluid as a biomarker for mucopolysaccharidosis type IIIA

Cory E. BystromiD, Kevin Douglass, Manju Gupta

PDFDOI
Citations
0

Abstract

BackgroundMucopolysaccharidosis type IIIA (MPS IIIA; Sanfilippo syndrome) is a fatal neurodegenerative lysosomal storage disorder caused by impaired degradation of heparan sulfate (HS). Despite rapid advances in gene and enzyme therapies, there remains a critical need for an analytically validated, quantitative biomarker that accurately reflects central nervous system (CNS) substrate burden. Such biomarker would be a valuable tool in assessing disease progression and monitoring therapeutic efficacy. ObjectiveThis study describes the method development, fit for purpose validation, and preliminary clinical application of a quantitative liquid chromatography-mass spectrometry (LC-MS/MS) assay for the HS-derived disaccharide N-sulfoglucosamine-glucuronic acid (GlcNS-GlcUA) in human cerebrospinal fluid (CSF), a critical biomarker for diagnosis, disease monitoring, and regulatory evaluation of emerging MPS IIIA therapies. MethodsA structurally defined GlcNS-GlcUA reference standard and its [13C6]-labeled internal standard were used in a derivatization and detection workflow employing 1-phenyl-3-methyl-5-pyrazolone labeling, and LC-MS/MS. ResultsThe method exhibited acceptable linearity across 0.005-0.500 nmol/mL (r [≥]0.9976), with intra- and inter-assay imprecision [≤]3.5%CV and accuracy within 95%-110% of nominal concentrations. No matrix or hemolysis interference or carryover was observed, and the analyte remained stable during freeze-thaw storage conditions. Application of the method to 12 CSF samples from patients with MPS IIIA demonstrated quantifiable GlcNS-GlcUA levels ranging from 0.0054 to 0.106 nmol/mL, confirming suitability for clinical and regulatory use. Comparison of the MPS IIIA sample results between the development laboratory and the contract research organization laboratory support robust inter-lab assay transfer. ConclusionsThis validated LC-MS/MS method establishes a regulatory-grade quantitative assay for measurement of CSF HS in MPS IIIA. Its high analytical sensitivity and reproducibility enable reliable assessment of CNS substrate reduction and pharmacodynamic response, supporting biomarker-driven therapeutic development and accelerated approval pathways for neuronopathic mucopolysaccharidoses.

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.

Sign in to file a reproducibility report.

Similarity Map
SelectedSame fieldCross-field
THISLe '25Douek '22Xu '25Lau '26Taherzadeh '23Gerken '23
62% semantic matchBiochemistry
Steven Q. Le, Alexander Sorensen, Soila Sukupolvi+5 more·Journal of Clinical Investigation·Aug 28, 2025· 4 citations