Structural DynamicsBiochemistryPeer-reviewed journal article
Recovering high-resolution information using energy filtering in MicroED
Abstract
Inelastic scattering poses a significant challenge in electron crystallography by elevating background noise and broadening Bragg peaks, thereby reducing the overall signal-to-noise ratio. This is particularly detrimental to data quality in structural biology, and the diffraction signal is relatively weak. These effects are aggravated even further by the decay of the diffracted intensities as result of accumulated radiation damage, and rapidly fading high-resolution information can disappear beneath the noise. Loss of high-resolution reflections can partly be mitigated using energy filtering, which removes inelastically scattered electrons and improves data quality and resolution. Here, we systematically compared unfiltered and energy-filtered MicroED data from proteinase K crystals, first collecting an unfiltered dataset followed directly by a second sweep using the same settings but with the energy filter inserted. Our results show that energy filtering consistently reduces noise, sharpenes Bragg peaks, and extends high-resolution information, even though the absorbed dose was doubled for the second pass. Importantly, our results demonstrate that high-resolution information can be recovered by inserting the energy filter slit. Energy-filtered datasets showed improved intensity statistics and better internal consistency, highlighting the effectiveness of energy filtering for improving data quality. These findings underscore its potential to overcome limitations in macromolecular electron crystallography, enabling higher-resolution structures with greater reliability.
- Citations
- 0
- FWCI
- 0.00
- Field percentile
- 4th percentile
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Energy filtering enables macromolecular MicroED data at sub-atomic resolution
Max T. B. Clabbers, Johan Hattne, … Tamir Gonen·Nature CommunicationsPeer-reviewed·Mar 6, 2025
- Characterization of energy filtering slit widths for MicroED data collection
Max T. B. Clabbers, Johan Hattne, … Tamir Gonen·Journal of Structural Biology XPeer-reviewed·Aug 14, 2026
- Experimental evidence for the benefits of higher X-ray energies for macromolecular crystallography
S. L. S. Storm, D. Axford, R. L. Owen·bioRxiv·Jan 21, 2021
- MicroED with the Falcon III direct electron detector
J. Hattne, M. W. Martynowycz, T. Gonen·bioRxiv·Apr 23, 2019
- Electron-counting in MicroED
J. Hattne, M. Martynowycz, … T. Gonen·bioRxiv·Jun 29, 2023
- Electron-counting MicroED data with the K2 and K3 direct electron detectors
M. T. B. Clabbers, M. W. Martynowycz, … T. Gonen·bioRxiv·Jul 4, 2022