henhaobio
Sign in

Biosensors and BioelectronicsGenetic & Genomic MedicinePeer-reviewed journal article

An ultrasensitive method for detecting mutations from short and rare cell-free DNA

Lin Wang, Yu Zhuang, Yue YuiD, Zhiwei GuoiD, Qiaomei GuoiD, Lihua Qiao, Xueqing WangiD, Xiaohui LiangiD, Pengpeng ZhangiD, Qifan LiiD, Chenjun HuangiD, Rong Cong, Yinghui LiiD, Bin Che, Huihui Xiong, Guomin Lin, Mingming Rao, Rongjun HuiD, Wei Ting WangiD, Guohua YangiD, Jiatao LouiD

PDFDOIPreprint
Citations
7
FWCI
0.62
Field percentile
top 40%

Abstract

BackgroundCell-free DNA (cfDNA) promises to serve as surrogate biomarkers for non-invasive molecular diagnostics. Disease-specific cfDNA, such as circulating tumor DNA (ctDNA), was short and rare, making the detection performance of the current targeted sequencing methods unsatisfying. MethodsThrough introducing a linear pre-amplification process and optimizing the adapter ligation with customized reagents, we developed the One-PrimER Amplification (OPERA) system. In this study, we examined its performance in detecting mutations of low variant allelic frequency (VAF) in various samples with short-sized DNA fragments. ResultsIn cell line-derived samples containing sonication-sheared DNA fragments with 50-150 bp (peak at 70-80 bp), OPERA was capable of detecting mutations as low as 0.0025% VAF, while CAPP-Seq only detected mutations of >0.03% VAF. Both single nucleotide variant and insertion/deletion can be detected by OPERA. In synthetic fragments as short as 80 bp with low VAF (0.03%-0.1%), the detection sensitivity of OPERA was significantly higher compared to that of droplet digital polymerase chain reaction. The error rate was 5.9x10-5 errors per base after de-duplication in plasma samples collected from healthy volunteers. By suppressing "single-strand errors", the error rate can be further lowered by >5 folds in EGFR T790M hotspot. In plasma samples collected from lung cancer patients, OPERA detected mutations in 57.1% stage I patients with 100% specificity and achieved a sensitivity of 30.0% in patients with tumor volume of less than 1 cm3. ConclusionsOPERA can effectively detect mutations in rare and highly-fragmented DNA. Trial registrationThis study has been registered on ChiCTR (ChiCTR1900024028) at 23rd June 2019. Keywords: cell-free DNA; library preparation; liquid biopsy; mutation; next-generation sequencing.

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.

Sign in to file a reproducibility report.