Combining Magnetoencephalography with Telemetric Streaming of Intracranial Recordings and Deep Brain Stimulation - a Feasibility Study
Mansoureh Fahimi HnazaeeiD, Matthias SureiD, George C. O’NeilliD, Gaetano Leogrande, Alfons SchnitzleriD, Esther FloriniD, Vladimir Litvak AiD
Abstract
The combination of subcortical Local Field Potential (LFP) recordings and stimulation with Magnetoencephalography (MEG) in Deep Brain Stimulation (DBS) patients enables the investigation of cortico-subcortical communication patterns and provides insights into DBS mechanisms. Until now, these recordings have been carried out in post-surgical patients with externalised leads. However, a new generation of telemetric stimulators makes it possible to record and stream LFP data in chronically implanted patients. Nevertheless, whether such streaming can be combined with MEG has not been tested. In the present study, we tested the most commonly implanted telemetric stimulator - Medtronic Percept PC with a phantom in three different MEG systems: two cryogenic scanners (CTF and MEGIN) and an experimental Optically Pumped Magnetometry (OPM)-based system. We found that when used in combination with the new SenSight segmented leads, Percept PC telemetric streaming only generates band-limited interference in the MEG at 123Hz and harmonics. However, the legacy streaming mode used with older lead models generates multiple, dense artefact peaks in the physiological range of interest (below 50Hz). The effect of stimulation on MEG critically depends on whether it is done in bipolar (between two contacts on the lead) or monopolar (between a lead contact and the stimulator case) mode. Monopolar DBS creates severe interference in the MEG as previously reported. However, we found that the OPM system is more resilient to this interference and could provide artefact-free measurements at least for limited frequency ranges. A resting measurement in the MEGIN system from a Parkinsons patient implanted with Percept PC and subthalamic SenSight leads revealed artefact patterns consistent with our phantom recordings. Moreover, analysis of LFP-MEG coherence in this patient showed oscillatory coherent networks consistent in their frequency and topography with those described in published group studies done with externalised leads. In conclusion, Percept PC telemetric streaming with SenSight leads is compatible with MEG. Furthermore, OPM sensors could provide additional new opportunities for studying DBS effects.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 11
- FWCI
- 1.87
- Field percentile
- top 14%
- Organism
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Deep brain stimulation device-specific artefacts in MEG recordings
Bahne H. Bahners, Roxanne Lofredi, … Esther Florin·Brain stimulationPeer-reviewed·Jan 1, 2024
- Stimulation related artifacts and a multipurpose template-based offline removal solution for a novel sensing-enabled deep brain stimulation device
Lauren H. Hammer, Ryan B. Kochanski, … Simon J Little·Stereotactic and Functional NeurosurgeryPeer-reviewed·Jan 1, 2022
- High-Precision Event Synchronization for Chronic Deep Brain Stimulation Local Field Potential Recordings
Sophia Sophia Gimple, Yasin Temel, … Marcus L.F. Janssen·bioRxiv·May 15, 2026
- A cardiac pulse signal affects local field potentials recorded from deep brain stimulation electrodes across clinical targets
Katherine Tourigny, Rory J. Piper, … Joram J. van Rheede·bioRxiv·Mar 5, 2026
- Deep brain stimulation creates information lesion through membrane depolarization
Eric Lowet, Krishnakanth Kondabolu, … Xue Han·bioRxiv·Mar 26, 2022
- Magnetic Temporal Interference For Noninvasive, High-resolution, and Localized Deep Brain Stimulation: Concept Validation