bioRxivBioengineeringPreprint
Structural and functional changes of pyramidal neurons at the site of an implanted microelectrode array in rat primary motor cortex
B. A. Gregory, C. H. Thompson, J. W. Salatino, M. J. Railing, A. F. Zimmerman, B. Gupta, K. Williams, J. A. Beatty, C. L. Cox, E. K. Purcell
Abstract
Devices capable of recording or stimulating neuronal signals have created new opportunities to understand normal physiology and treat sources of pathology in the brain. However, it is possible that the initial surgical insertion and subsequent tissue response to implanted electrodes may influence the nature of the signals detected or stimulated. In this study, we characterized structural and functional changes in pyramidal neurons surrounding silicon or polyimide-based electrodes implanted in the motor cortex of rats. Devices were captured in 300 m-thick tissue slices collected at the 1 or 6 week time point post-implantation, and individual neurons were assessed using a combination of whole-cell electrophysiology and 2-photon imaging. We observed disruption of the dendritic arbor of neurons near (<100 m) the device surface at both time points, as well as a significant reduction in spine densities. These effects were accompanied by a decrease in the frequency of spontaneous excitatory post-synaptic currents (sEPSCs), a loss in sag amplitude, and an increase in spike frequency adaptation at the 6 week time point. Interestingly, we also noted a significant increase in filopodial density in neurons surrounding devices. Results were similar for polyimide and silicon-based electrodes. We hypothesize that the effects observed in this study may contribute to the signal loss and instability that often accompany chronically implanted electrodes.
- organism: rat
- assay: electrophysiology
- assay: imaging
- research focus: cell type annotation
- research focus: cell signaling & trafficking
- approach: experimental assay
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Mud sticks after all: Chronically implanted microelectrodes but not electrical stimulation cause c-fos expression along their trajectory
Patrick Pflüger, Richard Pinnell, … Ulrich Hofmann·bioRxiv·Oct 16, 2017
- Planar Amorphous Silicon Carbide Microelectrode Arrays for Chronic Recording in Rat Motor Cortex
J. R. Abbott, E. N. Jeakle, … S. F. Cogan·bioRxiv·Nov 2, 2023
- Dynamic changes in structure and function of brain mural cells around chronically implanted microelectrodes
Steven M. Wellman, Adam M. Forrest, … Takashi D.Y. Kozai·BiomaterialsPeer-reviewed·Nov 12, 2024
- Utah Array Characterization and Histological Analysis of a Multi-Year Implant in Non-Human Primate Motor and Sensory Cortices
P. R. Patel, E. J. Welle, … C. A. Chestek·bioRxiv·Aug 27, 2022
- Neuronal functional connectivity is impaired in a layer dependent manner near the chronically implanted microelectrodes
K. Chen, A. Forrest, … T. D. Y. Kozai·bioRxiv·Nov 6, 2023
- Acute Increase of Excitatory Activity in Pyramidal Neurons of Rat Motor Cortex under Static Magnetic Field
Rebecca C. Klein, Stefan M. Goetz, … Angel V. Peterchev·bioRxiv·Jul 22, 2026