Micromotion derived fluid shear stress mediates peri-electrode gliosis through mechanosensitive ion channels
Alexandre TrotieriD, Enrico BagnoliiD, Tomasz WalskiiD, Judith EversiD, Eugenia PuglieseiD, Madeleine M. LoweryiD, Michelle KilcoyneiD, Una FitzGeraldiD, Manus Jonathan Paul BiggsiD
Abstract
Clinical applications for neural implant technologies are steadily advancing. Yet, despite clinical successes, neuroelectrode-based therapies require invasive neurosurgery and can subject local soft-tissues to micro-motion induced mechanical shear, leading to the development of peri-implant scaring. This reactive glial tissue creates a physical barrier to electrical signal propagation, leading to loss of device function. Although peri-electrode gliosis is a well described contributor to neuroelectrode failure, the mechanistic basis behind the initiation and progression of glial scarring remains poorly understood. Here, we develop an in silico model of electrode-induced shear stress to evaluate the evolution of the peri-electrode fluid-filled void, encompassing a solid and viscoelastic liquid/solid interface. This model was subsequently used to inform an in vitro parallel-plate flow model of micromotion mediated peri-electrode fluid shear stress. Ventral mesencephalic E14 rat embryonic in vitro cultures exposed to physiologically relevant fluid shear exhibited upregulation of gliosis-associated proteins and the overexpression of two mechanosensitive ion channel receptors, PIEZO1 and TRPA1, confirmed in vivo in a neural probe induced rat glial scar model. Finally, it was shown in vitro that chemical inhibition/activation of PIEZO1 could exacerbate or attenuate astrocyte reactivity as induced by fluid shear stress and that this was mitochondrial dependant. Together, our results suggests that mechanosensitive ion channels play a major role in the development of the neuroelectrode micromotion induced glial scar and that the modulation of PIEZO1 and TRPA1 through chemical agonist/antagonist may promote chronic electrode stability in vivo. Graphical abstract O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=144 SRC="FIGDIR/small/523766v1_ufig1.gif" ALT="Figure 1"> View larger version (41K): org.highwire.dtl.DTLVardef@962f03org.highwire.dtl.DTLVardef@1e8a6adorg.highwire.dtl.DTLVardef@116cbb6org.highwire.dtl.DTLVardef@19830da_HPS_FORMAT_FIGEXP M_FIG C_FIG HighlightsO_LIPeri-electrode void progression is mediated by fluid flow shear stress C_LIO_LIOscillatory fluid flow shear stress replicates neuroelectrode glial scarring in vitro C_LIO_LIAstrocyte PIEZO1 and TRPA1 are upregulated at the peri-electrode region in response to electrode micromotion C_LIO_LIPIEZO1 pharmaceutical activation diminishes shear stress-induced gliosis C_LIO_LIPIEZO1 chemical inhibition exacerbates gliosis and reduces mitochondrial functions C_LI
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 25
- FWCI
- 3.02
- Field percentile
- top 7%
- Organism
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Fluid shear stress promotes glial-mediated neurotoxicity in vitro via purinergic signaling
Sarah Tenney, Christopher Streilein, … R. Chase Cornelison·bioRxiv·Apr 29, 2025
- Ultrastructural analysis of neuroimplant-parenchyma interfaces uncover remarkable neuroregeneration along-with barriers that limit the implant electrophysiological functions
Aviv Sharon, Nava Shmoel, … Micha E. Spira·Frontiers in NeurosciencePeer-reviewed·Nov 22, 2021
- An actuated neural probe architecture for reducing gliosis-induced recording degradation
T. L. Massey, L. S. Kuo, … M. M. Maharbiz·bioRxiv·Jul 30, 2018
- In vivo spatiotemporal dynamics of astrocyte reactivity following neural electrode implantation
S. P. Savya, F. Li, … T. D. Y. Kozai·bioRxiv·Jul 1, 2022
- Mud sticks after all: Chronically implanted microelectrodes but not electrical stimulation cause c-fos expression along their trajectory
Patrick Pflüger, Richard Pinnell, … Ulrich Hofmann·bioRxiv·Oct 16, 2017
- Mechanical flexibility reduces the foreign body response to long- term implanted microelectrodes in rabbit cortex
Harbaljit S Sohal, Gavin J Clowry, … Stuart N Baker·bioRxiv·Jun 14, 2016