bioRxivBiophysicsPreprint
An Order of Magnitude Signal-to-Noise Improvement of Magnetic Resonance Spectra using a Segmented-Overlap Fourier-Filtering and Averaging (SOFFA) Approach.
Abstract
Segmented-Overlap Fourier-Filtering and Averaging (SOFFA) data acquisition method is described in detail for magnetic resonance spectroscopy. In this work the four processes that encompass the SOFFA data acquisition method are detailed: (i) oversampling spectral segments, (ii) Fourier block-filtering, (iii) segment-overlap averaging, and (iv) decimation. Three experimental examples are shown. Conventional Continuous Wave (CW) Electron Paramagnetic Resonance (EPR) is compared to SOFFA-CW of a single reduced [4Fe-4S]+ (S=1/2) at concentrations of 1 mM, 100 {micro}M, and 10 {micro}M showing an average increase in concentration sensitivity by a factor of 5.6. Experimental comparison of CW and SOFFA nonadiabatic rapid scan (SOFFA-NARS) data with similar filter parameters and field-modulation amplitude demonstrates a factor of 10.3 in signal-to-noise improvement for a 150 {micro}M sitedirected spin-labeled Hemoglobin in 82% glycerol at 18C. Conventional and SOFFA rapid scan (SOFFA-RS) data was collected for a minuscule amount of lithium phthalocyanine (LiPC) and a factor of 9.6 in signal-to-noise improvement is demonstrated. The signal-tonoise improvements were made for the same data acquisition times on standard commercial instruments. This method can be implemented to perform real-time segmented processing and, combined with more sophisticated averaging methods, will push the state-of-the-art sensitivity in magnetic resonance spectroscopy.
- Citations
- 0
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Magnetic Resonance Spectroscopy Spectral Registration Using Deep Learning
David J. Ma, Yanting Yang, … Jia Guo·Journal of Magnetic Resonance ImagingPeer-reviewed·Jul 4, 2023
- MR Spectroscopy without Water Suppression using the Gradient Impulse Response Function
James B Bacon, Peter Jezzard, William T Clarke·Magnetic Resonance in MedicinePeer-reviewed·May 5, 2026
- Converting Spectral Evoked-to-Background Ratio intoTime-Domain Signal-to-Noise Ratio - Validation for HighFrequency Oscillations
Gerald Fischer, Jens Haueisen, … Markus Köfler·MethodsXPeer-reviewed·Sep 17, 2025
- Impacts of Simultaneous Multislice Acquisition on Sensitivity and Specificity in fMRI
Benjamin B. Risk, Mary C. Kociuba, Daniel B. Rowe·NeuroImagePeer-reviewed·Feb 3, 2018
- Frequency Shift Imaging Using an Adiabatic SLR Self-Refocused Pulse for Positive-Contrast SPION Imaging at 7T
Akbar Alipour, Madison Chiu, … Priti Balchandani·bioRxiv·Sep 28, 2026
- Magnetic Resonance Spectroscopy Frequency and Phase Correction Using Convolutional Neural Networks
David J. Ma, Hortense Le, … Jia Guo·Magnetic Resonance in MedicinePeer-reviewed·Dec 21, 2021