Nature CommunicationsBiophysicsPeer-reviewed journal article
Preparation of oxygen-sensitive proteins for high-resolution cryoEM structure determination using (an)aerobic blot-free vitrification
B. D. CookiD, Sarah M. NarehoodiD, Kelly L. McGuireiD, Yizhou LiiD, F. Akif TezcaniD, Mark A. HerzikiD
- Citations
- 7
- FWCI
- 2.28
- Field percentile
- top 13%
Abstract
High-quality grid preparation for single-particle cryogenic electron microscopy (cryoEM) remains a bottleneck for routinely obtaining high-resolution structures. The issues that arise from traditional grid preparation workflows are particularly exacerbated for oxygen-sensitive proteins, including metalloproteins, whereby oxygen-induced damage and alteration of oxidation states can result in protein inactivation, denaturation, and/or aggregation. Indeed, 99% of the current structures in the EMBD were prepared aerobically and limited successes for anaerobic cryoEM grid preparation exist. Current practices for anaerobic grid preparation involve a vitrification device located in an anoxic chamber, which presents significant challenges including temperature and humidity control, optimization of freezing conditions, costs for purchase and operation, as well as accessibility. Here, we present a streamlined approach that allows for the (an)aerobic vitrification of oxygen-sensitive proteins using an automated aerobic blot-free grid vitrification device - the SPT Labtech chameleon. This robust workflow allows for high-resolution structure determination of dynamic, oxygen-sensitive proteins, of varying complexity and molecular weight.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Need for speed: Examining protein behaviour during cryoEM grid preparation at different timescales
D. P. Klebl, M. S. C. Gravett, … s. P. muench·bioRxiv·May 14, 2020
- CryoCycle your grids: Plunge vitrifying and reusing clipped grids to advance cryoEM democratization
Viacheslav Serbynovskyi, Jing Wang, … Alex J. Noble·bioRxiv·Jan 23, 2024
- Tuning ice thickness using the chameleon for high-quality cryoEM data collection
Kelly L. McGuire, B. D. Cook, … Mark A. Herzik·bioRxiv·May 1, 2024
- Automated cryo-EM sample preparation by pin-printing and jet vitrification
R. B. G. Ravelli, F. J. T. Nijpels, … P. Peters·bioRxiv·May 28, 2019
- Foam film vitrification for cryo-EM
Yue Zhang, Biplob Nandy, … Jan Löwe·Nature CommunicationsPeer-reviewed·Jul 4, 2025
- Vitrification after multiple rounds of sample application and blotting improves particle density on cryo-electron microscopy grids.
J. Snijder, A. J. Borst, … D. Veesler·bioRxiv·Dec 15, 2016