henhaobio
Sign in

bioRxivBioengineeringPreprint

Mechanistic Evaluation of Amplification Lag in Paper-Based Colorimetric Loop Mediated Isothermal Amplification (LAMP) and Its Reduction by BSA Pre-Coating

Taehong KimiD, Gopal PallaiD, Bibek RautiD, Mohit S. VermaiD, Arezoo M. ArdekaniiD

PDFDOI
Citations
0

Abstract

Colorimetric loop-mediated isothermal amplification (LAMP) on microfluidic paper-based analytical devices (PADs) offers a low-cost, disposable, and equipment-free alternative to liquid LAMP assays. However, amplification on PADs is consistently slower, by 5-46%, than reactions in tubes. To identify the origin of this delay, we evaluated heat transfer, diffusion in porous cellulose, and nonspecific adsorption of LAMP components across both high- and low-copy input regimes. Our results show that once thermal equilibrium is reached, reduced effective diffusion is the dominant contributor to the kinetic lag at low copy numbers, whereas nonspecific adsorption becomes the primary barrier at higher template concentrations. Pre-coating the paper with bovine serum albumin (BSA) mitigates adsorption. It narrows the tube-to-paper gap, thereby accelerating amplification of the SARS-CoV-2 ORF7ab synthetic gene by an average of 6 minutes, from 1E3 to 1E5 copies per reaction. These findings provide a mechanistic basis for the copy-number-dependent behavior of PAD LAMP and offer simple, low-cost strategies to improve the speed and reliability of PAD nucleic acid assays.

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.