Using spIsoNet to address the preferred-orientation problem in cryoEM reconstructions
Abstract
Cryogenic electron microscopy (cryoEM) is now routinely used for high-resolution structure determination of biological macromolecules. However, many biological specimens exhibit varying degrees of preferred orientation on cryoEM grids, resulting in uneven sampling of three-dimensional Fourier space. This orientation bias produces anisotropic reconstruction artifacts and, in severe cases, can exacerbate particle misalignment during iterative refinement, thereby limiting the success rate of near-atomic resolution cryoEM structure determination. This protocol provides a practical guide for applying spIsoNet, a self-supervised deep-learning method, to mitigate preferred-orientation issues in cryoEM reconstructions. We describe two complementary workflows: (1) map Anisotropy Correction to correct anisotropic artifacts of cryoEM maps and (2) particle Misalignment Correction, which integrates spIsoNet with RELION external reconstruction to improve particle-pose estimation. We demonstrate these workflows using two influenza hemagglutinin (HA) trimer datasets representing moderate and severe degrees of preferred-orientation bias. The protocol includes installation instructions, parameter-selection guidance, quality-control checkpoints and troubleshooting advice, and can typically be completed in [~]7 hours on a workstation equipped with four NVIDIA A100 GPUs. Together, these workflows provide step-by-step guidance for using the open-source spIsoNet software to mitigate the preferred-orientation problem directly from experimental data.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 0
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Overcoming the preferred orientation problem in cryoEM with self-supervised deep-learning
Yun-Tao Liu, Hongcheng Fan, … Z. Hong Zhou·Nature MethodsPeer-reviewed·Nov 18, 2024
- Addressing preferred orientation in single-particle cryo-EM through AI-generated auxiliary particles.
- Plunge freezing tweezers with ultrasonic excitation for reducing preferred particle orientation in cryo-EM
J Hruby, Mischa Flór, … Ulrich Joseph Lorenz·bioRxiv·Oct 4, 2026
- Ab initio CryoEM maps minimizing preferred orientation problems in heterogeneous mixtures: ReconSIREN
David Herreros, Carlos Óscar S. Sorzano, J.M. Carazo·bioRxiv·Oct 10, 2026
- Cryo-EM map anisotropy can be attenuated by map post-processing and a new method for its estimation
Rubén Sánchez-García, Guillaume Gaullier, … Javier Vargas·International Journal of Molecular SciencesPeer-reviewed·Apr 2, 2024
- cFAR and Relative Signal: Diagnosing Preferred Orientation in Single-Particle Cryo-EM
Valentin Peretroukhin, Michael McLean, Ali Punjani·bioRxiv·Aug 18, 2026