bioRxivBiophysicsPreprint
Plunge freezing tweezers with ultrasonic excitation for reducing preferred particle orientation in cryo-EM
J HrubyiD, Mischa FlóriD, Constantin R. KrügeriD, Marcel DrabbelsiD, Ulrich Joseph LorenziD
Abstract
Preferred particle orientation, which results from the adsorption of proteins to the air-water interface, is a frequently encountered issue in single-particle cryo-electron microscopy (cryo-EM). Particles then present only a limited number of views, which are oversampled during data acquisition at the expense of throughput, while other views may be missing altogether. In severe cases, a high-resolution reconstruction becomes unattainable. We have recently established that ultrasonic excitation of the sample during vitrification improves the angular distribution by detaching particles from the air-water interface and reshuffling their orientations. Here, we describe an implementation of this principle for a plunge freezing apparatus, in which the ultrasonic transducer is integrated into the head of the pair of tweezers holding the sample, and show that this design is able to reduce preferred orientation. We demonstrate this for hemagglutinin, the canonical example of preferred orientation, and show that the fraction of side and tilted views increases with the excitation amplitude. This allows us to obtain a complete reconstruction of the trimer at 2.5 [A].
- Citations
- 0
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Overcoming Preferred Orientation in Cryo-EM With Ultrasonic Excitation During Vitrification
Harry M. Williams, Wyatt A. Curtis, … Ulrich Joseph Lorenz·bioRxiv·Sep 14, 2025
- Factors affecting macromolecule orientations in thin films formed in cryo-EM
S. Yadav, V. Kutti Ragunath·bioRxiv·Nov 6, 2023
- Laser Flash Melting Cryo-EM Samples to Overcome Preferred Orientation
Monique S. Straub, Oliver F. Harder, … Ulrich Joseph Lorenz·Nature MethodsPeer-reviewed·Aug 28, 2025
- Addressing preferred orientation in single-particle cryo-EM through AI-generated auxiliary particles.
- Near-atomic resolution reconstructions from in situ revitrified cryo samples
G. Bongiovanni, O. F. Harder, … U. J. Lorenz·bioRxiv·Feb 20, 2023
- A Surfactant Cocktail Overcomes Air-Water Interface Artifacts in Single-Particle CryoEM
Suzanne E. Enos, B. Cook, … Mark A. Herzik·bioRxiv·Mar 18, 2026