Dual-axis Volta phase plate cryo-electron tomography of Ebola virus-like particles reveals actin-VP40 interactions
Abstract
Cryo-electron tomography (cryo-ET) is a pivotal imaging technique for studying the structure of pleomorphic enveloped viruses and their interactions with the host at native conditions. Owing to the limited tilting range of samples with a slab geometry, electron tomograms suffer from so-called missing wedge information in Fourier space. In dual-axis cryo-ET, two tomograms reconstructed from orthogonally oriented tilt series are combined into a tomogram with improved resolution as the missing wedge information is reduced to a pyramid. Volta phase plate (VPP) allows to perform in-focus cryo-ET with high contrast transfer at low-resolution frequencies and thus its application may improve the quality of dual-axis tomograms. Here, we compare dual-axis cryo-ET with and without VPP on Ebola virus-like particles to visualize and segment viral and host cell proteins within the membrane-enveloped filamentous particles. Dual-axis VPP cryo-ET reduces the missing wedge information and ray artifacts arising from the weighted back-projection during tomogram reconstruction, thereby minimizing ambiguity in the analysis of crowded environments and facilitating 3D segmentation. We show that dual-axis VPP tomograms provide a comprehensive description of macromolecular organizations such as nucleocapsid assembly states, the distribution of glycoproteins on the viral envelope and asymmetric arrangements of the VP40 layer in non-filamentous regions of virus-like particles. Our data reveal actin filaments within virus-like particles in close proximity to the viral VP40 scaffold, suggesting a direct interaction between VP40 and actin filaments. Dual-axis VPP cryo-ET provides more complete 3D information at high contrast and allows for better interpretation of macromolecule interactions and pleomorphic organizations. HighlightsO_LIVolta phase plate dual-axis cryo-electron tomography provides high contrast tomography data with reduced back-projection ray artifacts and missing wedge information in Fourier space C_LIO_LIVolta phase plate dual-axis cryo-electron tomography facilitates interpretation of protein-membrane interactions C_LIO_LIVolta phase plate dual-axis cryo-electron tomography reduces ambiguity in manual 3D rendering and markedly improves 3D isosurface modeling C_LIO_LIEbola virus-like particles contain actin filaments in close proximity to the VP40 layer C_LI
02 /Specification & Classification
Click any tag to browse matching papersReproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Intracellular Ebola Virus nucleocapsid assembly revealed by in situ cryo-electron tomography.
R. Watanabe, D. Zyla, … E. O. Saphire·bioRxiv·Dec 1, 2023
- Using the Volta phase plate with defocus for cryo-EM single particle analysis
R. Danev, D. Tegunov, W. Baumeister·bioRxiv·Nov 3, 2016
- Nucleocapsid condensation drives Ebola viral factory maturation and dispersion
M. Vallbracht, B. S. Bodmer, … P. Chlanda·bioRxiv·Nov 6, 2023
- Ebola and Marburg virus matrix layers are locally ordered assemblies of VP40 dimers
- Subcellular Characterization of the Molecular Determinants of Ebola Virus VP40 Trafficking and Assembly
Tyler Huth, Ella Wiggenhorn, … William Wan·bioRxiv·May 8, 2026
- Characterization Standard for In-situ Cryo-electron Tomography
Mallak Ali, Joshua Hutchings, … Mohammadreza Paraan·bioRxiv·May 22, 2026