PLoS ONEGenomicsPeer-reviewed journal article
Duplex Proximity Sequencing (Pro-Seq): A method to improve DNA sequencing accuracy without the cost of molecular barcoding redundancy
Joel PeliD, Wendy W. Y. ChoiiD, Amy O. Leung, Gosuke ShibaharaiD, Laura GelinasiD, Milenko Despotovic, W. Lloyd UngiD, Andre Marziali
Abstract
A challenge in the clinical adoption of cell-free DNA (cfDNA) liquid biopsies for cancer care is their high cost compared to potential reimbursement. The most common approach used in liquid biopsies to achieve high specificity detection of circulating tumor DNA (ctDNA) among a large background of normal cfDNA is to attach molecular barcodes to each DNA template, amplify it, and then sequence it many times to reach a low-error consensus. In applications where the highest possible specificity is required, error rate can be lowered further by independently detecting the sequences of both strands of the starting cfDNA. While effective in error reduction, the additional sequencing redundancy required by such barcoding methods can increase the cost of sequencing up to 100-fold over standard next-generation sequencing (NGS) of equivalent depth.\n\nWe present a novel library construction and analysis method for NGS that achieves comparable performance to the best barcoding methods, but without the increase in sequencing and subsequent sequencing cost. Named Proximity-Sequencing (Pro-Seq), the method merges multiple copies of each template into a single sequencing read by physically linking the molecular copies so they seed a single sequencing cluster. Since multiple DNA copies of the same template are compared for consensus within the same cluster, sequencing accuracy is improved without the use of redundant reads. Additionally, it is possible to represent both senses of the starting duplex in a single cluster. The resulting workflow is simple, and can be completed by a single technician in a work day with minimal hands on time.\n\nUsing both cfDNA and cell line DNA, we report the average per-mutation detection threshold and per-base analytical specificity to be 0.003% and >99.9997% respectively, demonstrating that Pro-Seq is among the highest performing liquid biopsy technologies in terms of both sensitivity and specificity, but with greatly reduced sequencing costs compared to existing methods of comparable accuracy.
- Citations
- 21
- FWCI
- 0.83
- Field percentile
- top 34%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Accurate detection of circulating tumor DNA using nanopore consensus sequencing
A. Marcozzi, M. Jager, … J. de Ridder·bioRxiv·Jul 14, 2020
- Paired plus-minus sequencing is an ultra-high throughput and accurate method for dual strand sequencing of DNA molecules
Alexandre Pellan Cheng, Itai Rusinek, … Dan Avi Landau·bioRxiv·Aug 11, 2025
- Comparison of double-stranded and single-stranded cfDNA library construction methods for targeted genome and methylation sequencing
Jianchao Zheng, Zhilong Li, … Yuying Wang·bioRxiv·Jan 12, 2022
- Rapid and highly-specific generation of targeted DNA sequencing libraries enabled by linking capture probes with universal primers
Joel Pel, Amy Leung, … Andre Marziali·PLoS ONEPeer-reviewed·Dec 5, 2018
- Adaptor Template Oligo-Mediated Sequencing (ATOM-Seq): A versatile and ultra-sensitive UMI-based NGS library preparation technology, for use with cfDNA and cfRNA.
Thomas L. Dunwell, Simon C. Dailey, … Guoliang Fu·Scientific ReportsPeer-reviewed·Feb 4, 2021
- Next Generation-Targeted Amplicon Sequencing (NG-TAS): An optimised protocol and computational pipeline for cost-effective profiling of circulating tumour DNA
Meiling Gao, Maurizio Callari, … Carlos Caldas·Genome MedicinePeer-reviewed·Jan 4, 2019