Frontiers in NeuroscienceNeurosciencePeer-reviewed journal article
Engineered biological neural networks on high density CMOS micro electrode arrays
Jens DuruiD, Joël KüchleriD, Stephan J. IhleiD, Csaba ForróiD, Aeneas BernardiiD, Sophie GirardiniD, Julian HengsteleriD, Stephen Wheeler, János VörösiD, Tobias RuffiD
Abstract
In bottom-up neuroscience, questions on neural information processing are addressed by engineering small but reproducible biological neural networks of defined network topology in vitro. The network topology can be controlled by culturing neurons within polydimethylsiloxane (PDMS) microstructures that are combined with microelectrode arrays (MEAs) for electric access to the network. However, currently used glass MEAs are limited to 256 electrodes and pose a limitation to the spatial resolution as well as the design of more complex microstructures. The use of high density complementary metal-oxide-semiconductor (CMOS) MEAs greatly increases the spatiotemporal resolution, enabling sub-cellular readout and stimulation of neurons in defined neural networks. Unfortunately, the non-planar surface of CMOS MEAs complicates the attachment of PDMS microstructures. To overcome the problem of axons escaping the microstructures through the ridges of the CMOS MEA, we stamp-transferred a thin film of hexane-diluted PDMS onto the array such that the PDMS filled the ridges at the contact surface of the microstructures without clogging the axon guidance channels. Moreover, we provide an impedance-based method to visualize the exact location of the microstructures on the MEA and show that our method can confine axonal growth within the PDMS microstructures. Finally, the high spatiotemporal resolution of the CMOS MEA enabled us to show that we can guide action potentials using the unidirectional topology of our circular multi-node microstructure.
- Citations
- 57
- FWCI
- 4.86
- Field percentile
- top 3%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Design, implementation, and functional validation of a new generation of microneedle 3D high-density CMOS multi-electrode array for brain tissue and spheroids
Lisa Mapelli, Olivier Dubochet, … Alessandro Maccione·bioRxiv·Aug 11, 2022
- The CMU Array. A 3D Nano-Printed, Fully Customizable Ultra-High-Density Microelectrode Array
Mohammad Sadeq Saleh, Sandra M. Ritchie, … Rahul P. Panat·bioRxiv·Aug 23, 2019
- CHIME: CMOS-hosted in-vivo microelectrodes for massively scalable neuronal recordings
Mihály Köllő, Romeo Rácz, … Andreas T. Schaefer·Frontiers in NeurosciencePeer-reviewed·Aug 11, 2020
- Large-area electrical imaging having single neuron resolution using 236,880 electrodes CMOS-MEA technology
Ikuro Suzuki, Naoki Matsuda, … Y. Ishibashi·bioRxiv·Nov 9, 2022
- Stress-actuated Flexible Microelectrode Arrays for Activity Recording in 3D Neuronal Cultures
João Serra, José C. Mateus, … Diana C. Leitão·Lab on a ChipPeer-reviewed·Jan 1, 2025
- Growing neuronal islands on multi-electrode arrays using an Accurate Positioning-μCP device
Robert Samhaber, Manuel Schottdorf, … Fred Wolf·bioRxiv·Oct 1, 2015