Best for the Eye, Not for the Algorithm: Anisotropy in Fitting Atomic Models in Cryo-EM
Abstract
Most atomic model refinement methods in cryo-EM fit models to the reconstructed density map and effectively treat Fourier voxels as equally reliable. However, the uncertainty in the estimation of Fourier coefficients is highly anisotropic, primarily due to the common variability in SNR in different frequency shells and the distribution of particle images across viewing directions. First-principles arguments suggest that atomic models should be fitted to particle images rather than volumes; this strategy may be computationally demanding. We show that under certain modeling choices, fitting atomic models to weighted volumes is equivalent to fitting directly to particle images. Furthermore, we argue that various proxies can be used to capture this and other sources of uncertainty and distortions. We propose that the principle can be implemented in most atomic model-fitting software with relative ease, using information readily available in existing pipelines. As a proof of concept, we extracted the necessary information from standard RELION runs and fed it into a modified version of Servalcat in which we implemented a reinterpreted version of the idea.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 0
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Direct calculation of cryo EM and crystallographic model maps for real-space refinement
A. Urzhumtsev, L. Urzhumtseva, V. Y. Lunin·bioRxiv·Jul 17, 2022
- Cryo-EM single particle structure refinement and map calculation using Servalcat
K. Yamashita, C. M. Palmer, … G. N. Murshudov·bioRxiv·May 4, 2021
- Iterative model-based density improvement yields better atomic structures from cryo-EM maps
A. J. Jakobi, M. Wilmanns, C. Sachse·bioRxiv·Mar 29, 2017
- Variable Resolution Maps (VRM) in CCTBX and Phenix: Accounting For Local Resolution In cryoEM
Pavel V. Afonine, Paul D. Adams, Alexandre Urzhumtsev·bioRxiv·Mar 28, 2026
- FSC-Q: A CryoEM map-to-atomic model quality validation based on the local Fourier Shell Correlation
E. Ramirez-Aportela, D. Maluenda, … C. O. S. Sorzano·bioRxiv·May 12, 2020
- Real-space quantum-based refinement for cryo-EM: Q|R#3
Lum Wang, Holger Kruse, … Małgorzata Biczysko·Acta Crystallographica Section D Structural BiologyPeer-reviewed·Nov 19, 2020