Ground Truth-Based Evaluation of False Discovery Rate and Statistical Power in DIA Proteomics
Jay M. YarbroiD, Ya HuangiD, Vishwajeeth PagalaiD, Yingxue FuiD, Zhen Wang, Long WuiD, Xusheng Wang, Anthony A. HighiD, Stephanie D. ByrumiD, Junmin PengiD, Zuo-Fei YuaniD
Abstract
Data-independent acquisition (DIA) mass spectrometry enables rapid proteomic quantification, yet the reliability of statistical inference in DIA-based protein quantification remains incompletely understood. Here, we systematically evaluated missingness, false discovery rate (FDR), and statistical power, defined as true positive rate (i.e. sensitivity or recall), using technical replicates and a spike-in benchmark with known ground truth. Analysis of 18 HeLa replicates revealed persistent, abundance-dependent missingness. In the spike-in experiment with five replicates, human peptides were titrated against a stable yeast background, allowing fold changes (FCs) to be compared with expected values. Across comparisons with log2FCs ranging from 0.2 to 2.5, the nominal BH-FDR substantially underestimated the true FDR. For example, at a BH-FDR threshold of 0.05, the true FDR was [~]0.2. Statistical power was [~]40% for a log2FC of 0.2 and increased to nearly 100% for a log2FC of 2.5. Additional incorporation of FC thresholds improved the true FDR for large-FC comparisons, with slight loss of power, but markedly reduced sensitivity for small-FC comparisons. Together, these results indicate that nominal FDR does not necessarily reflect actual error rates in DIA proteomics and that DIA performance is influenced by protein abundance and expected fold changes. This study provides a framework for experimental design and data interpretation in DIA-based proteomic studies.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 0
- Organism
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- JUMPlion improves quantitative DIA proteomics through ion-level recovery of missing values
Yingxue Fu, Zuo-Fei Yuan, … Anthony A. High·bioRxiv·May 1, 2026
- Recommendations for Quantitative Data-Independent Acquisition (DIA) Proteomics using Controlled Quantitative Experiments (CQEs)
Andrew Michael Frey, Frances R. Sidgwick, … Matthias Trost·bioRxiv·Sep 22, 2025
- diagFDR: Verifiable False Discovery Rate Reporting in Proteomics via Scope, Calibration, and Stability Diagnostics
Marie Chion, Alexandre Godmer, … Quentin Giai Gianetto·bioRxiv·Apr 20, 2026
- Matrix-matched calibration curves for assessing analytical figures of merit in quantitative proteomics
L. K. Pino, B. C. Searle, … M. J. MacCoss·bioRxiv·Jul 30, 2019
- proDA: Probabilistic Dropout Analysis for Identifying Differentially Abundant Proteins in Label-Free Mass Spectrometry
Constantin Ahlmann-Eltze, Simon Anders·bioRxiv·May 1, 2020
- Extensive and accurate benchmarking of DIA acquisition methods and software tools using a complex proteomic standard
Clarisse Gotti, Florence Roux‐Dalvai, … Arnaud Droit·Journal of Proteome ResearchPeer-reviewed·Sep 2, 2021