Sign in
Cell BiologybioRxiv
Preprint

High contrast staining for serial block face scanning electron microscopy without uranyl acetate

Adolfo Odriozola, Jaime Llodrá, Julika RadeckeiD, Céline Ruegsegger, Stefan TschanziD, Smita SaxenaiD, Rohr StephaniD, Benoît ZuberiD

Abstract

1Serial block face scanning electron microscopy (SBFSEM) is an increasingly popular method for investigating the three-dimensional ultrastructure of large biological samples. Prior to imaging, samples are typically chemically fixed, stained with osmium and uranyl acetate, and subsequently embedded in resin. The purpose of staining is to provide image contrast and reduce specimen charging under the electron beam, which is detrimental to the quality of imaging. Obtaining, using, and disposing of uranyl acetate is getting increasingly cumbersome in many countries due to new regulations on the handling of radioactive substances. Therefore, we developed an alternative staining procedure that does not rely on the use of uranium or any other radioactive substance. This procedure provides excellent contrast and efficiently reduces specimen charging.

PDFDOI

02 /Specification & Classification

Click any tag to browse matching papers

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.