bioRxivBiochemistry
Factors affecting macromolecule orientations in thin films formed in cryo-EM
Abstract
The formation of a vitrified thin film embedded with randomly oriented macromolecules is an essential prerequisite for cryogenic sample electron microscopy. Most commonly, this is achieved using the plunge freeze method described nearly 40 years ago. Although this is a robust method, the behaviour of different macromolecules shows great variation upon freezing and often needs to be optimized to obtain an isotropic, high-resolution reconstruction. For a macromolecule in such a film, the probability of encountering the air-water interface in the time between blotting and freezing and adopting preferred orientations is very high. 3D reconstruction using preferentially oriented particles often leads to anisotropic and uninterpretable maps. Currently, there are no general solutions to this prevalent issue, but several approaches largely focusing on sample preparation with the use of additives and novel grid modifications have been attempted. In this study, the effect of physical and chemical factors on the orientations of macromolecules was investigated through an analysis of select well-studied macromolecules and important parameters that determine the behaviour of proteins on cryo-EM grids were revealed. These insights highlight the nature of interactions that cause preferred orientations and can be utilized to systematically address orientation bias for any given macromolecule and provide a framework to design small-molecule additives to enhance sample stability and behaviour.
- assay: cryo-EM
- research focus: host-pathogen & immune response
- research focus: protein folding & dynamics
- approach: experimental assay
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Plunge freezing tweezers with ultrasonic excitation for reducing preferred particle orientation in cryo-EM
J Hruby, Mischa Flór, … Ulrich Joseph Lorenz·bioRxiv·Oct 4, 2026
- Overcoming Preferred Orientation in Cryo-EM With Ultrasonic Excitation During Vitrification
Harry M. Williams, Wyatt A. Curtis, … Ulrich Joseph Lorenz·bioRxiv·Sep 14, 2025
- Laser Flash Melting Cryo-EM Samples to Overcome Preferred Orientation
Monique S. Straub, Oliver F. Harder, … Ulrich Joseph Lorenz·Nature MethodsPeer-reviewed·Aug 28, 2025
- Foam film vitrification for cryo-EM
Yue Zhang, Biplob Nandy, … Jan Löwe·Nature CommunicationsPeer-reviewed·Jul 4, 2025
- A Surfactant Cocktail Overcomes Air-Water Interface Artifacts in Single-Particle CryoEM
Suzanne E. Enos, B. Cook, … Mark A. Herzik·bioRxiv·Mar 18, 2026
- A novel cryo-electron microscopy support film based on 2D crystal of HFBI protein