Computationally guided design of a metastasis-on-a-chip platform for quantitative evaluation of chemotactic cues in developmental cancers
Catherine MurphyiD, Luka JarciD, Alessia CadavereiD, Emilia Cioffi, Maider Badiola-MateosiD, David Fernandez, Nathalia Gomez-Jimenez, Jaume MoraiD, Josep SamitieriD, Aránzazu VillasanteiD
Abstract
Metastatic dissemination is initiated by tumor cells interpreting spatially organized biochemical and biophysical cues that remain difficult to reproduce using conventional migration assays. Here, we developed a computationally guided metastasis-on-a-chip (MET-on-a-chip) platform based on the concept of the Minimally Functional Unit (MFU), in which only the biological components required to answer a defined experimental question are incorporated. The platform consists of two independent culture chambers connected through an array of confined microchannels that permits diffusion of soluble factors while constraining tumor cell migration. Rather than relying on empirical optimization, finite-element COMSOL simulations were first used to predict molecular transport, define growth factor loading conditions, identify biologically relevant exposure regions, and guide the rational design of the microfluidic assay. Computational predictions were experimentally validated using 70-kDa FITC-dextran diffusion and VEGF release studies, confirming the formation of stable spatial concentration gradients across the microfluidic platform. The simulations further demonstrated that both growth factor loading and cell positioning relative to the predicted gradients critically influenced assay performance, leading to the optimization of the platform through spatial reconfiguration of the tumor compartment. Using the optimized configuration, we compared the migratory responses of neuroblastoma, Ewing sarcoma, and osteosarcoma cells to vascular (VEGF-A165) and lymphatic (VEGF-C) chemotactic cues. VEGF-C significantly increased migration through the microchannel array in Ewing sarcoma and osteosarcoma cells, whereas VEGF-A165 produced no significant effect. In contrast, neuroblastoma cells exhibited minimal migration under either condition, revealing tumor-specific differences in responsiveness to VEGF signaling. Together, these findings establish a computationally guided workflow for the rational design of metastasis-on-a-chip assays, in which predictive modeling informs experimental design before biological validation. By substantially reducing empirical trial-and-error while enabling quantitative control over growth factor exposure, this strategy provides a robust framework for developing minimally functional microphysiological systems capable of dissecting individual steps of the metastatic cascade under experimentally defined conditions. Translational Impact StatementMetastatic dissemination remains one of the greatest clinical challenges in pediatric oncology, yet experimental models capable of quantitatively evaluating early migratory events remain limited. The computationally guided MET-on-a-Chip workflow presented here provides a human-relevant platform in which soluble microenvironmental cues can be systematically investigated under controlled and predictive conditions. Although demonstrated here using VEGF-A165 and VEGF-C, the platform can be readily adapted to study virtually any chemotactic factor, cytokine, extracellular vesicle population, or therapeutic candidate involved in metastatic dissemination. The modular MFU design allows biological complexity to be incorporated progressively as dictated by the scientific question, providing a flexible framework for future applications. In the longer term, this workflow could be combined with patient-derived tumor cells, organoids, or biopsy material to investigate patient-specific metastatic behavior and evaluate anti-metastatic therapeutic strategies in a personalized setting. Beyond identifying pro-migratory signaling pathways, the platform may serve as a preclinical tool to prioritize compounds capable of preventing tumor cell dissemination before evaluation in more complex animal models or clinical studies.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 0
- Organism
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- The effects of luminal and trans-endothelial fluid flows on the extravasation and tissue invasion of tumor cells in a 3D in vitro microvascular platform
C. Hajal, L. Ibrahim, … R. Kamm·bioRxiv·Sep 23, 2020
- Protruding Geometry Provides Potential Homing Sites of Circulating Tumor Cells
Yeqing Leng, Bo Li·bioRxiv·Oct 17, 2026
- Homing Choices of Breast Cancer Cells Revealed by Tissue Specific Invasion and Extravasation Lab-on-a-chip Platforms
B. Firatligil-Yildirir, G. Bati-Ayaz, … O. Yalcin-Ozuysal·bioRxiv·Sep 25, 2020
- Development and characterization of a biotechnological model suitable for studies of tumor cell extravasation and intravasation
Ekaterina V. Ivanovskaya, Georgii A. Bykov, … Anastasia N. Sveshnikova·bioRxiv·Dec 16, 2025
- A 3D Tumor-on-a-chip Platform to Identify Drugs that Block Breast Cancer Cell Intravasation
Narmada M Perera, Diogo Coutinho, … Ana Magalhães·bioRxiv·Mar 22, 2026
- 3D spheroid-microvasculature-on-a-chip for tumor-endothelium mechanobiology interplay