bioRxivBiochemistry
Structural Insights into the Venus flytrap Mechanosensitive Ion Channel Flycatcher1
S. Jojoa-Cruz, K. Saotome, C. C. Tsui, W.-H. Lee, M. S. P. Sansom, S. E. Murthy, A. Patapoutian, A. B. Ward
Abstract
Flycatcher1 (FLYC1), a MscS homolog, has recently been identified as a candidate mechanosensitive (MS) ion channel involved in Venus flytrap prey recognition. FLYC1 is larger and its sequence diverges from previously studied MscS homologs, suggesting it has unique structural features that contribute to its function. Here, we characterized FLYC1 by cryo-electron microscopy, molecular dynamics simulations, and electrophysiology. Akin to bacterial MscS and plant MSL1 channels, we find that FLYC1 central core includes side portals in the cytoplasmic cage that regulate ion conduction, by identifying critical residues that modulate channel conductance. Topologically unique cytoplasmic flanking regions can adopt up or down conformations, making the channel asymmetric. Disruption of an up conformation-specific interaction severely delays channel deactivation by 40-fold likely due to stabilization of the channel open state. Our results illustrate novel structural features and likely conformational transitions that regulate mechano-gating of FLYC1.
- organism: plant (other)
- assay: cryo-EM
- assay: electrophysiology
- research focus: synaptic & neural circuits
- approach: experimental assay
- approach: mechanistic / dynamical model
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Stretch-activated ion channels identified in the touch-sensitive structures of carnivorous Droseraceae plants
- State-specific morphological deformations of the lipid bilayer explain mechanosensitive gating of MscS ion channels
Y. C. Park, B. Reddy, … J. D. Faraldo-Gomez·bioRxiv·Jul 1, 2022
- MscM uses a novel gating mechanism for bacterial mechanosensitive channels
Giorgos Hiotis, Thomas Walz·bioRxiv·Mar 25, 2026
- Ether anesthetics prevents touch-induced trigger hair calcium-electrical signals excite the Venus flytrap
S. Scherzer, S. Huang, … R. Hedrich·bioRxiv·Aug 18, 2021
- Charged Pore-lining Residues are Required for Normal Channel Kinetics in the Eukaryotic Mechanosensitive Ion Channel MSL1
A. M. Schlegel, E. Haswell·bioRxiv·Jul 27, 2020
- Nonpolar Residues in the Presumptive Pore-Lining Helix of Mechanosensitive Channel MSL10 Influence Channel Behavior and Confirm a Non-Conducting Function
G. Maksaev, J. Shoots, … E. Haswell·bioRxiv·Feb 12, 2018