Unbend: Correction of local beam-induced sample motion in cryo-EM images using a 3D spline model
Lingli KongiD, Ximena ZottigiD, Johannes ElferichiD, Nikolaus GrigorieffiD
Abstract
The exposure of frozen biological samples to the high-energy electron beam in a cryo-electron microscope commonly leads to beam-induced sample motion and distortions. Previously, we described Unblur, which is part of our cisTEM software to correct for beam-induced motion based on the alignment of full frames in a movie collected during the beam exposure (Grant et al., 2015). However, Unblur cannot accommodate motion due to more localized sample bending and distortions. Here, we present Unbend, extending Unblur by incorporating local motion correction using a three-dimensional cubic spline model. The 3D spline model is constructed using cubic B-splines along the exposure time axis, and bicubic B-splines within movie frames. Unbend is integrated into our cisTEM software with a new local motion visualization panel within the cisTEM graphical user interface. We processed movie frames from various in-situ sample types, including whole cells, lamellae, and cell lysates, to analyze motion behavior across different specimen types. To quantify the improvement in high-resolution signal, we utilized the 2D template matching method, which operates independently of the motion correction process, to search large ribosomal subunits from the motion-corrected micrographs. Overall, the signal-to-noise ratio of detected particles improved by 3-8% across different samples compared with full-frame aligned micrographs, while the number of detected target particles increased by up to [~]300%. The total and Von Mises equivalent strain shows a deformation scale of less than 1% in most of the samples, confirming that our model induces minimal additional distortion. Furthermore, we processed micrograph montages to study motion patterns across an entire sample, revealing considerable variance in distortion scale within the same sample, suggesting a complex underlying mechanism.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 0
- FWCI
- 0.00
- Field percentile
- 0th percentile
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Anisotropic Correction of Beam-induced Motion for Improved Single-particle Electron Cryo-microscopy
Shawn Zheng, Eugene Palovcak, … David Agard·bioRxiv·Jul 4, 2016
- A Bayesian approach to beam-induced motion correction in cryo-EM single-particle analysis
J. Zivanov, T. Nakane, S. Scheres·bioRxiv·Aug 3, 2018
- Increasing vitrification temperature improves the cryo-electron microscopy reconstruction
- Atomic modeling of radiation damage in cryoelectron microscopy datasets
Alexander Shtyrov, Hugh D. Wilson, Garib N. Murshudov·bioRxiv·Aug 21, 2026
- A Mechanism for Beam-Induced Motion in Cryo-Electron Microscopy
R. E. Thorne·IUCrJPeer-reviewed·Mar 26, 2020
- High Resolution Single Particle Cryo-Electron Microscopy using Beam-Image Shift
A. Cheng, E. T. Eng, … B. Carragher·bioRxiv·Apr 26, 2018