High Resolution Single Particle Cryo-Electron Microscopy using Beam-Image Shift
A. Cheng, E. T. Eng, L. Alink, W. J. Rice, K. D. Jordan, L. Y. Kim, C. S. Potter, B. Carragher
Abstract
Automated data acquisition is now used widely for the single-particle averaging approach to reconstruction of three-dimensional (3D) volumes of biological complexes preserved in vitreous ice and imaged in a transmission electron microscope (cryo-EM). Automation has become integral to this method because of the very large number of particle images required to be averaged in order to overcome the typically low signal-to-noise ratio of these images.\n\nFor optimal efficiency, all automated data acquisition software packages employ some degree of beam-image shift because this method is fast and accurate (+/- 0.1 m). Relocation to a targeted area under low-dose conditions can only be achieved using stage movements in combination with multiple iterations or long relaxation times, both reducing efficiency. It is, however, well known that applying beam-image shift induces beam-tilt and hence structure phase error. A {pi}/4 phase error is considered as the worst that can be accepted, and is used as an argument against the use of any beam-image shift for high resolution data collection.\n\nIn this study, we performed cryo-EM single-particle reconstructions on a T20S proteasome sample using applied beam-image shifts corresponding to beam tilts from 0 to 10 mrad. To evaluate the results we compared the FSC values, and examined the water density peaks in the 3D map. We conclude that the {pi}/4 phase error does not limit the validity of the 3D reconstruction from single-particle averaging beyond the {pi}/4 resolution limit.
02 /Specification & Classification
Click any tag to browse matching papersReproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- High-resolution cryo-EM using beam-image shift at 200 keV
J. N. Cash, S. Kearns, … M. A. Cianfrocco·IUCrJPeer-reviewed·Oct 29, 2020
- Beam image-shift accelerated data acquisition for near-atomic resolution single-particle cryo-electron tomography
J. Bouvette, H.-F. Liu, … A. Bartesaghi·bioRxiv·Sep 24, 2020
- High-resolution cryo-EM reconstructions in the presence of substantial aberrations
R. Bromberg, Y. Guo, … Z. Otwinowski·bioRxiv·Oct 8, 2019
- Anisotropic Correction of Beam-induced Motion for Improved Single-particle Electron Cryo-microscopy
Shawn Zheng, Eugene Palovcak, … David Agard·bioRxiv·Jul 4, 2016
- Increasing vitrification temperature improves the cryo-electron microscopy reconstruction
- Achieving Better Than 3 A Resolution By Single Particle Cryo-EM At 200 keV
M. A. Herzik, M. Wu, G. C. Lander·bioRxiv·May 25, 2017