Pulse train gating to improve signal generation for in vivo two-photon fluorescence microscopy
Shaun A. EngelmanniD, Alankrit Tomar, Aaron L. Woods, Andrew K. DunniD
Abstract
SignificanceTwo-photon microscopy is used routinely for in vivo imaging of neural and vascular structure and function in rodents with a high resolution. Image quality, however, often degrades in deeper portions of the cerebral cortex. Strategies to improve deep imaging are therefore needed. We introduce such a strategy using gates of high repetition rate ultrafast pulse trains to increase signal level. AimWe investigate how signal generation, signal-to-noise ratio (SNR), and signal-to-background ratio (SBR) improve with pulse gating while imaging in vivo mouse cerebral vasculature. ApproachAn electro-optic modulator is used with a high-power (6 W) 80 MHz repetition rate ytterbium fiber amplifier to create gates of pulses at a 1 MHz repetition rate. We first measure signal generation from a Texas Red solution in a cuvette to characterize the system with no gating and at a 50%, 25%, and 12.5% duty cycle. We then compare signal generation, SNR, and SBR when imaging Texas Red-labeled vasculature using these conditions. ResultsWe find up to a 6.73-fold increase in fluorescent signal from a cuvette when using a 12.5% duty cycle pulse gating excitation pattern as opposed to a constant 80 MHz pulse train. We verify similar increases for in vivo imaging to that observed in cuvette testing. For deep imaging we find pulse gating to result in a 2.95-fold increase in SNR and a 1.37-fold increase in SBR on average when imaging mouse cortical vasculature at depths ranging from 950 m to 1050 m. ConclusionsWe demonstrate that a pulse gating strategy can either be used to limit heating when imaging superficial brain regions or used to increase signal generation in deep regions. These findings should encourage others to adopt similar pulse gating excitation schemes for imaging neural structure through two-photon microscopy.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 3
- FWCI
- 0.36
- Field percentile
- top 48%
- Organism
- Assay
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- High-throughput deep tissue two-photon microscopy at kilohertz frame rates
- A 40 MHz femtosecond laser repetition frequency divider for enhanced two-photon imaging
Shiming Tang·bioRxiv·Jul 2, 2023
- Dual-plane 3-photon microscopy with remote focusing
Kevin Takasaki, Dmitri A. Tsyboulski, Jack Waters·Biomedical Optics ExpressPeer-reviewed·Oct 8, 2019
- An evaluation of resonant scanning as a high-speed imaging technique for two-photon imaging of cortical vasculature
Annie Zhou, Shaun A. Engelmann, … Andrew K. Dunn·Biomedical Optics ExpressPeer-reviewed·Feb 2, 2022
- Optical constraints on two-photon voltage imaging
F. Phil Brooks, Hunter C. Davis, … Adam E. Cohen·NeurophotonicsPeer-reviewed·Aug 13, 2024
- Retroreflective beam multiplexing enables high-throughput two-photon voltage imaging in vivo