Cryo-TEM simulations of amorphous radiation-sensitive samples using multislice wave propagation.
Abstract
Image simulation plays a central role in the development and practice of high-resolution electron microscopy, including transmission electron microscopy of frozen-hydrated specimens (cryo-EM). Simulating images with contrast that matches the contrast observed in experimental images remains challenging, especially for amorphous samples. Current state-of-the-art simulators apply post hoc scaling to approximate empirical solvent contrast, attenuated image intensity due to specimen thickness, and amplitude contrast. This practice fails for images that require spatially variable scaling, e.g., simulations of a crowded or cellular environment. Modeling both the signal and the noise accurately is necessary to simulate images of biological specimens with contrast that is correct on an absolute scale. The "Frozen-Plasmon" method is introduced which explicitly models spatially variable inelastic scattering processes in cryo-EM specimens. This approach produces amplitude contrast that depends on the atomic composition of the specimen, reproduces the total inelastic mean free path as observed experimentally, and allows for the incorporation of radiation damage in the simulation. These improvements are quantified using the matched-filter concept to compare simulation and experiment. The Frozen-Plasmon method, in combination with a new mathematical formulation for accurately sampling the tabulated atomic scattering potentials onto a Cartesian grid, is implemented in the open-source software package cisTEM.
- assay: cryo-EM
- research focus: software / tool
- research focus: benchmarking
- research focus: imputation
- research focus: dimensionality reduction
- approach: deep learning
- approach: statistical model
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Radiation dose effects in correlative X-ray / cryo-electron microscopy of frozen hydrated biological samples
Thorsten B. Blum, Vincent Oliéric, … Volodymyr M. Korkhov·Acta Crystallographica Section D Structural BiologyPeer-reviewed·Feb 25, 2026
- Exploring the potential for scanning electron microscopy/focused ion beam - based diffraction for screening cryo-transmission electron microscopy samples
Eric Woods, Christoph Wigge, … Baptiste Gault·bioRxiv·Sep 25, 2025
- Pulsed-electron illumination does not reduce beam damage for imaging biological macromolecules
Vishal Kumar, Julika Radecke, … Henning Stahlberg·Nature CommunicationsPeer-reviewed·Jun 17, 2026
- Atomic modeling of radiation damage in cryoelectron microscopy datasets
Alexander Shtyrov, Hugh D. Wilson, Garib N. Murshudov·bioRxiv·Aug 21, 2026
- Narrow-beam geometry improves the efficiency of cryo-EM
Senik Matinyan, Pavel Filipčík, … Jan Pieter Abrahams·bioRxiv·Jul 8, 2026
- Increasing vitrification temperature improves the cryo-electron microscopy reconstruction