Acta Crystallographica Section D Structural BiologyBiophysicsPeer-reviewed journal article
Radiation dose effects in correlative X-ray / cryo-electron microscopy of frozen hydrated biological samples
Thorsten B. BlumiD, Vincent OliériciD, Ana DíaziD, Takashi IshikawaiD, Volodymyr M. KorkhoviD
Abstract
In cryo-electron microscopy (cryo-EM), imaging of biological specimens is restricted by the limited field of view and by sample thickness. Hard X-ray imaging, with its ability to penetrate samples several tens of micrometers thick, offers a complementary approach for high-resolution visualization. A major concern is whether cryo-preserved samples can withstand the handling conditions at synchrotron facilities without excessive icing, and whether the radiation exposure during X-ray imaging compromises specimen integrity, thereby hindering subsequent attempts to achieve high-resolution 3D reconstructions via cryo-EM. To evaluate this, we deposited apoferritin samples on a cryo-EM grid, exposed them to varied X-ray doses typical for X-ray tomography experiments at a synchrotron facility, and subsequently analysed the exposed particles by cryo-EM. Despite the apparent damage sustained throughout the experiment, the samples remained amenable to cryo-EM analysis, with structural details at a resolution of [~]4 [A] at the highest absorbed X-ray dose of 100 MGy. By comparison, a similar cryo-EM dataset of the apoferritin particles that were not exposed to X-rays but were mounted on the same cryo-EM grid, resulted in a 3D reconstruction at 3.17 [A] resolution. Thus, while radiation damage may limit the high-resolution information in specimens processed by cryo-X-ray tomography, the cryo-preserved biological material exposed to these high X-ray doses can be still used for subsequent cryo-EM workflows aiming to obtain structural biology insights at intermediate to high resolution. These findings lay the groundwork for an integrated imaging workflow that combines X-ray and cryo-EM techniques to enable multiscale analysis of thick vitrified biological specimens.
- assay: cryo-EM
- assay: imaging
- research focus: protein structure prediction
- approach: experimental assay
- Citations
- 0
- FWCI
- 0.00
- Field percentile
- 7th percentile
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Atomic modeling of radiation damage in cryoelectron microscopy datasets
Alexander Shtyrov, Hugh D. Wilson, Garib N. Murshudov·bioRxiv·Aug 21, 2026
- Increasing vitrification temperature improves the cryo-electron microscopy reconstruction
- Pulsed-electron illumination does not reduce beam damage for imaging biological macromolecules
Vishal Kumar, Julika Radecke, … Henning Stahlberg·Nature CommunicationsPeer-reviewed·Jun 17, 2026
- Super-resolution fluorescence imaging of cryosamples does not limit achievable resolution in cryoEM
Mart G.F. Last, Willem E. M. Noteborn, … Thomas Harry Sharp·Journal of Structural BiologyPeer-reviewed·Oct 31, 2023
- Sub-3 A resolution protein structure determination by single-particle cryo-EM at 100 keV
Dimple Karia, Fujiet Koh, … Abhay Kotecha·StructurePeer-reviewed·Jul 30, 2025
- Narrow-beam geometry improves the efficiency of cryo-EM
Senik Matinyan, Pavel Filipčík, … Jan Pieter Abrahams·bioRxiv·Jul 8, 2026