Hemoperfusion of pigs with a carbon-cellulose cartridge: a pilot study revealing a new animal model of extended anaphylactic shock
Bálint András BartaiD, Tamás RadovitsiD, Sylvia SpiesshoferiD, Albert J. Husznai, Andrea DobosiD, László MészárosiD, Tamás MészárosiD, Gergely Tibor KozmaiD, Réka FacskóiD, László DézsiiD, Nacsa János, Joshua A. JackmaniD, Béla Péter MerkelyiD, János SzebeniiD
Abstract
To investigate the immune mechanisms underlying extracorporeal circulation-associated anaphylactoid reactions, we inserted externally perfused cartridges into the venous circulation of pigs, including a cellulose-coated activated-charcoal adsorbent (Adsorba(R) 300C), a polysulfone hollow-fiber membrane hemofilter, and polypropylene hollow-fiber-based heart-lung machine gas-exchange oxygenators. Blood was circulated using a roller pump, and the animals were monitored for systemic and pulmonary arterial pressures (SAP, PAP) changes, blood levels of complement C3a, thromboxane B2, and hemoglobin, blood cell counts and hematocrit. None of the cartridges caused major changes in these endpoints except the Adsorba(R) 300C, which displayed a fulminant anaphylactoid reaction characterized by profound hypotension, maximal pulmonary hypertension, hemoconcentration, thrombocytopenia and a surge of C3a and thromboxane B2, i.e., hallmarks of complement activation-related pseudoallergy. Within 15 min, the reaction advanced to profound hemodynamic collapse, which was managed with norepinephrine and cardiopulmonary resuscitation. After brief rebound hypertension, shock recurred despite repeated rounds of resuscitation until death. Considering that major adverse reactions with overlapping symptoms have been reported in humans subjected to hemoperfusion with the same cartridge, this porcine model provides clinically relevant insights into the mechanisms of extracorporeal circulation-induced anaphylactoid responses. Furthermore, the Adsorba(R) 300C-induced physiological changes along the immune-cardiopulmonary axis represents a new animal model for irreversible cardiovascular collapse escalating into shock.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 0
- Organism
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Calibration of a Closed-loop Model of Porcine Aortic Hemodynamics during Hemorrhage
Sadman Sadid, Matthew Eden, … Carlos Alberto Figueroa·bioRxiv·Feb 2, 2026
- A translational porcine model to assess the graded impact of hemorrhage and aortic occlusion on cardiovascular hemodynamics and renal perfusion
Fahim Usshihab Mobin, Micaela K Gomez, … Elaheh Rahbar·bioRxiv·Feb 9, 2026
- Cardiorespiratory physiological perturbations after acute smoke-induced lung injury and during extracorporeal membrane oxygenation support in sheep
S. Chemonges·bioRxiv·Jun 12, 2016
- Vicious cycle of hemodynamic perturbation and endothelial injury in development and progression of pulmonary arterial hypertension
Y. Deng, K. R. Chaudhary, … D. J. Stewart·bioRxiv·Oct 16, 2023
- In a Canine Model of Septic Shock, Cardiomyopathy Occurs Independent of Catecholamine Surges and Cardiac Microvascular Ischemia
Verity J. Ford, Willard N. Applefeld, … Charles Natanson·bioRxiv·Feb 5, 2024
- Cardiovascular effects of intravenous colforsin in normal and acute respiratory acidosis canine models: a dose-response study
T. Itami, K. Hanazono, … K. Yamashita·bioRxiv·Feb 22, 2019