A Spatial Transcriptomics Study of the Brain-Electrode Interface in Rat Motor Cortex
Abstract
The study of the foreign body reaction to implanted electrodes in the brain is an important area of research for the future development of neuroprostheses and experimental electrophysiology. After electrode implantation in the brain, microglial activation, reactive astrogliosis, and neuronal cell death create an environment immediately surrounding the electrode that is significantly altered from its homeostatic state. To uncover physiological changes potentially affecting device function and longevity, spatial transcriptomics was implemented in this preliminary study to identify changes in gene expression driven by electrode implantation. This RNA-sequencing technique (10x Genomics, Visium) uses spatially coded, RNA-binding oligonucleotides on a microscope slide to spatially identify each sequencing read. For these experiments, sections of rat motor cortex implanted with Michigan-style silicon electrodes were mounted on the Visium slide for processing. Each tissue section was labeled for neurons and astrocytes using immunohistochemistry to provide a spatial reference for mapping each sequencing read relative to the device tract. Results from rat motor cortex at 24 hours, 1 week, and 6 weeks post implantation showed up to 5811 differentially expressed genes between implanted and non-implanted tissue sections. Many of these genes are related to biological mechanisms previously reported in studies of the foreign body response to implanted electrodes, while others are novel to this study. These results will provide a foundation for future work to both improve and measure the effects of gene expression on the long-term stability of recordings from implanted electrodes in the brain. Ongoing work will expand on these initial observations as we gain a better understanding of the dynamic, molecular changes taking place in the brain in response to electrode implantation.
02 /Specification & Classification
Click any tag to browse matching papers- Organism
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- A systematic analysis of brain tissue response to microelectrode material and size with single-cell spatial transcriptomics
Cort H. Thompson, Anirban Chakraborty, … Erin K. Purcell·bioRxiv·Mar 16, 2026
- Gene Expression Changes in Cultured Reactive Rat Astrocyte Models and Comparison to Device-Associated Effects in the Brain
Ti’Air E. Riggins, Quentin A. Whitsitt, … Erin K. Purcell·bioRxiv·Jan 6, 2023
- In vivo spatiotemporal dynamics of astrocyte reactivity following neural electrode implantation
S. P. Savya, F. Li, … T. D. Y. Kozai·bioRxiv·Jul 1, 2022
- Mechanical flexibility reduces the foreign body response to long- term implanted microelectrodes in rabbit cortex
Harbaljit S Sohal, Gavin J Clowry, … Stuart N Baker·bioRxiv·Jun 14, 2016
- Structural and functional changes of pyramidal neurons at the site of an implanted microelectrode array in rat primary motor cortex
B. A. Gregory, C. H. Thompson, … E. K. Purcell·bioRxiv·Sep 15, 2022
- Mud sticks after all: Chronically implanted microelectrodes but not electrical stimulation cause c-fos expression along their trajectory
Patrick Pflüger, Richard Pinnell, … Ulrich Hofmann·bioRxiv·Oct 16, 2017