A 3D-printed flow-cell for on-grid purification of electron microscopy samples directly from lysate
K. Ramlaul, Z. Feng, C. Canavan, N. de Martin Garrido, D. Carreno, M. Crone, K. E. Jensen, B. Li, H. Barnet, D. T. Riglar, P. S. Freemont, D. Miller, C. H. S. Aylett
Abstract
While recent advances in cryo-EM, coupled with single particle analysis, have the potential to allow structure determination in a near-native state from vanishingly few individual particles, this vision has yet to be realised in practise. Requirements for particle numbers that currently far exceed the theoretical lower limits, challenges with the practicalities of achieving high concentrations for difficult-to-produce samples, and inadequate sample-dependent imaging conditions, all result in significant bottlenecks preventing routine structure determination using cryo-EM. Therefore, considerable efforts are being made to circumvent these bottlenecks by developing affinity purification of samples on-grid; at once obviating the need to produce large amounts of protein, as well as more directly controlling the variable, and sample-dependent, process of grid preparation. In this proof-of-concept study, we demonstrate a further practical step towards this paradigm, developing a 3D-printable flow-cell device to allow on-grid affinity purification from raw inputs such as whole cell lysates, using graphene oxide-based affinity grids. Our flow-cell device can be interfaced directly with routinely-used laboratory equipment such as liquid chromatographs, or peristaltic pumps, fitted with standard chromatographic (1/16") connectors, and can be used to allow binding of samples to affinity grids in a controlled environment prior to the extensive washing required to remove impurities. Furthermore, by designing a device which can be 3D printed and coupled to routinely used laboratory equipment, we hope to increase the accessibility of the techniques presented herein to researchers working towards single-particle macromolecular structures.
02 /Specification & Classification
Click any tag to browse matching papers- Assay
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- 3D printed cell culture grid holders for improved cellular specimen preparation in cryo-electron microscopy
F. Faessler, B. Zens, … F. K. Schur·bioRxiv·Jun 12, 2020
- Application of monolayer graphene to cryo-electron microscopy grids for high-resolution structure determination
A. V. Grassetti, M. B. May, J. H. Davis·bioRxiv·Jul 28, 2023
- Affinity-tag-based microfluidic protein isolation enables high-resolution Cryo-EM from minimal starting material
Michael Zimmermann, Dorothee Elaine Schneider, … Thomas Braun·bioRxiv·May 28, 2026
- Development of immobilized antibody-based affinity grid strategy and application in on-grid purification of target proteins for high-resolution cryo-EM
Qiaoyu Zhao, Xiaoyu Hong, … Cong Yao·bioRxiv·Jan 17, 2024
- High Yield Monolayer Graphene Grids for Near-Atomic Resolution Cryo-Electron Microscopy
- EasyGrid: A versatile platform for automated cryo-EM sample preparation and quality control
Olivier Gemin, Victor Armijo, … Gergely Papp·Nature MethodsPeer-reviewed·Jun 23, 2026