Strategies based on sum of peak intensities may better reflect protein expression than peak area integration in iTRAQ protein expression measurement by LC-MS/MS using a TripleTOF 5600+ platform
B. Burat, J. Gonzalez, F.-L. Sauvage, H. Aouad, H. Arnion, E. Pinault, P. Marquet, M. Essig
Abstract
In the field of quantitative proteomics, the Isobaric Tags for Relative & Absolute Quantitation (iTRAQ) technology has demonstrated efficacy for proteome monitoring despite its lack of a consensus for data handling. In this study, after peptide and protein identification, we compared the widespread quantitation method based on the calculation of MS/MS reporter ion peaks areas ratios (ProteinPilot) to the alternative method based on the calculation of ratios of the sum of peak intensities (jTRAQx (Quant)) and we processed output data with the in-house Customizable iTRAQ Ratios Calculator (CiR-C) algorithm. Quantitation based on peak area ratios displayed no significant linear correlation with Western blot quantitation. In contrast, quantitation based on the sum of peak intensities displayed a significant linear association with Western blot quantitation (non-zero slope; Pearson correlation coefficient test, r = 0.2962, p = 0.0099 **) with an average bias of 0.08747 {+/-} 0.5004 and 95% Limits of Agreement from - 0.8932 to 1.068. We proposed the Mascot-jTRAQx-CiR-C strategy as a simple yet powerful data processing adjunct to the iTRAQ technology.
02 /Specification & Classification
Click any tag to browse matching papersReproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Improved LC-MS chromatographic alignment increases the accuracy of label-free quantitative proteomics: Comparison of spectral counting versus ion intensity-based proteomic quantification strategies.
Daniel Ng, Jonathan D. Humphries, … Martin James Humphries·bioRxiv·Feb 24, 2017
- Direct Measurement of Synchronous Precursor Selection (SPS) Accuracy in Public Proteomics Datasets
Conor Jenkins, Aimee Rinas, Benjamin C. Orsburn·bioRxiv·May 24, 2019
- Bayesian Confidence Intervals for Multiplexed Proteomics Integrate Ion-Statistics with Peptide Quantification Concordance
Leonid Peshkin, Meera Gupta, … Martin Wühr·Molecular & Cellular ProteomicsPeer-reviewed·Jul 16, 2019
- Analysis of isobaric quantitative proteomic data using TMT-Integrator and FragPipe computational platform
Hui-Yin Chang, Yamei Deng, … Alexey I. Nesvizhskii·Nature CommunicationsPeer-reviewed·Mar 2, 2026
- LFAQ: towards unbiased label-free absolute protein quantification by predicting peptide quantitative factors
Cheng Chang, Zhiqiang Gao, … Fuchu He·Analytical ChemistryPeer-reviewed·Dec 10, 2018
- Prior Signal Acquisition Software Versions for Orbitrap Underestimate Low Isobaric Mass Tag Intensities, Without Detriment to Differential Abundance Experiments
Tom S. Smith, Anna Andrejeva, … Kathryn Susan Lilley·ACS Measurement Science AuPeer-reviewed·Mar 9, 2022