Surpassing the physical Nyquist limit to produce super-resolution cryo-EM reconstructions
Abstract
The resolution of cryo-EM reconstructions is fundamentally limited by the Nyquist frequency, which is half the sampling frequency of the detector and depends upon the magnification used. In principle, super-resolution imaging should enable reconstructions to surpass the physical Nyquist limit by increasing sampling frequency, yet there are no reports of reconstructions that do so. Here we report the use of super-resolution imaging with the K3 direct electron detector to produce super-resolution single-particle cryo-EM reconstructions significantly surpassing the physical Nyquist limit. We also present a comparative analysis of a sample imaged at four different magnifications. This analysis demonstrates that lower magnifications can be beneficial, despite the loss of higher resolution signal, due to the increased particle numbers imaged. To highlight the potential utility of lower magnification data collection, we produced a 3.5 [A] reconstruction of jack bean urease with particles from a single micrograph. O_FIG O_LINKSMALLFIG WIDTH=111 HEIGHT=200 SRC="FIGDIR/small/675397v3_ufig1.gif" ALT="Figure 1"> View larger version (23K): org.highwire.dtl.DTLVardef@1579481org.highwire.dtl.DTLVardef@d6bf96org.highwire.dtl.DTLVardef@bc4bc0org.highwire.dtl.DTLVardef@116412_HPS_FORMAT_FIGEXP M_FIG C_FIG
02 /Specification & Classification
Click any tag to browse matching papers- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Specimen-Dependent Sampling and Signal Limitations Govern the Effectiveness of Low-Magnification Super-Resolution in Cryo-EM
Chun-Hsiung Wang, Kuen‐Phon Wu, Yuan‐Chih Chang·bioRxiv·Sep 12, 2026
- Post-acquisition super resolution for cryo-electron microscopy
R. N. Burton-Smith, K. Murata·bioRxiv·Jun 9, 2023
- Practical considerations for using K3 cameras in CDS mode for high-resolution and high-throughput single particle cryo-EM
M. Sun, C. M. Azumaya, … D. A. Agard·bioRxiv·Nov 8, 2020
- Sub-3 A resolution protein structure determination by single-particle cryo-EM at 100 keV
Dimple Karia, Fujiet Koh, … Abhay Kotecha·StructurePeer-reviewed·Jul 30, 2025
- Achieving Better Than 3 A Resolution By Single Particle Cryo-EM At 200 keV
M. A. Herzik, M. Wu, G. C. Lander·bioRxiv·May 25, 2017
- Super-resolution fluorescence imaging of cryosamples does not limit achievable resolution in cryoEM
Mart G.F. Last, Willem E. M. Noteborn, … Thomas Harry Sharp·Journal of Structural BiologyPeer-reviewed·Oct 31, 2023