ACS OmegaBioengineeringPeer-reviewed journal article
Development of an on-chip fluorescence anisotropy immunoassay for human C-peptide secretion reveals a general roadmap for tracer optimization
Yufeng WangiD, Nitya GulatiiD, Romario RegeenesiD, Adriana MiglioriniiD, Amanda OakieiD, M. Cristina NostroiD, Jonathan V. RocheleauiD
Abstract
Fluorescence anisotropy immunoassays (FAIAs) are widely used to quantify the concentration of target proteins based on competition with a tracer in binding a monoclonal antibody. We recently designed an FAIA to measure mouse C-peptide secretion from living islets in a continuous-flow microfluidic device (InsC-chip). To develop an assay for human C-peptide, our initial selection of antibody-tracer pairings revealed the need to optimize both the dynamic range and the binding kinetics to measure the assay on-chip effectively. Here, we present strategies for developing an on-chip FAIA using two different monoclonal antibodies to achieve both a large dynamic range and high temporal resolution. The two monoclonal antibodies (Ab1 & Ab2) to human C-peptide initially showed low dynamic range and slow kinetics, preventing them from being used in an on-chip assay. To shorten the time-to-reach equilibrium for Ab1, we reengineered the tracer based on a comparison between the human and mouse C-peptide sequences, resulting in > 30-fold shorter time-to-reach equilibrium. To increase the relatively small dynamic range for Ab2, we used partial epitope mapping and targeted point mutations to increase the dynamic range by 45%. Finally, we validated both FAIAs by measuring depolarization-induced insulin secretion from individual hESC-islets in our InsC-chip. These strategies provide a general roadmap for developing FAIAs with high sensitivity and sufficiently fast kinetics to be measured in continuous-flow microfluidic devices.
- organism: human
- organism: mouse
- assay: fluorescence / live-cell microscopy
- research focus: cell type annotation
- research focus: cell signaling & trafficking
- approach: experimental assay
- Citations
- 2
- FWCI
- 0.46
- Field percentile
- 49th percentile
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Insulin secretion chip (InS-chip) reveals two peaks within first-phase that temporally coincide with a transition in glucose metabolism.
Y. Wang, R. Regeenes, … J. V. Rocheleau·bioRxiv·Mar 7, 2023
- An Antibody Cocktail-Based Immunoaffinity-LC-MS Method Enabled Ultra-Sensitive and Robust Quantification of Circulating Proinsulin Proteoforms and C-peptide
Qingqing Shen, Wang Cao, … Jun Qu·Analytical ChemistryPeer-reviewed·Aug 28, 2025
- Instrument-free quantitative detection of analytes using a novel combo lateral flow assay
Xiaolin Sheng, Navya Saxena, Xiaofeng Xia·ACS Applied Bio MaterialsPeer-reviewed·Jan 13, 2026
- Rapid and Highly Sensitive Detection of Fentanyl and its Analogs by a Novel Chemiluminescence Immunoassay
J.-y. Zhao, M. Uddin, … X. Xia·bioRxiv·Nov 15, 2023
- Affinity-based selection of anti-Feline Leukaemia Virus p27 monoclonal antibodies for efficient lateral flow assay development
Hadyn Duncan, Elisabeth Domingo-Contreras, … Ana Camacho·Analytical BiochemistryPeer-reviewed·Nov 20, 2025
- A Competitive Fluorescence Immunoassay Based on Intermolecular Quenching Using an N-Terminally Fluorescent-Labeled IgG Antibody
Keisuke Fukunaga, Takayoshi Watanabe, Takahiro Hohsaka·Biochemical and Biophysical Research CommunicationsPeer-reviewed·Feb 11, 2026