Multiplex PCR method for MinION and Illumina sequencing of Zika and other virus genomes directly from clinical samples
Joshua QuickiD, Nathan D. GrubaughiD, Steven T. PullaniD, Ingra Morales ClaroiD, Andrew D. SmithiD, Karthik GangavarapuiD, Glenn OliveiraiD, Refugio Robles‐SikisakaiD, Thomas F. RogersiD, Nathan BeutleriD, Dennis R. BurtoniD, Lia Laura Lewis‐XimeneziD, Jaqueline Góes de JesusiD, Marta GiovanettiiD, Sarah Catherine HilliD, Allison BlackiD, Trevor BedfordiD, Miles W. CarrolliD, Márcio Roberto Teixeira NunesiD, Luíz Carlos Júnior AlcântaraiD, Éster Cerdeira SabinoiD, Sally A. BaylisiD, Nuno Rodrigues FariaiD, Matthew LooseiD, Jared T. SimpsoniD, , Nicholas James LomaniD
Abstract
Genome sequencing has become a powerful tool for studying emerging infectious diseases; however, genome sequencing directly from clinical samples without isolation remains challenging for viruses such as Zika, where metagenomic sequencing methods may generate insufficient numbers of viral reads. Here we present a protocol for generating coding-sequence complete genomes comprising an online primer design tool, a novel multiplex PCR enrichment protocol, optimised library preparation methods for the portable MinION sequencer (Oxford Nanopore Technologies) and the Illumina range of instruments, and a bioinformatics pipeline for generating consensus sequences. The MinION protocol does not require an internet connection for analysis, making it suitable for field applications with limited connectivity. Our method relies on multiplex PCR for targeted enrichment of viral genomes from samples containing as few as 50 genome copies per reaction. Viral consensus sequences can be achieved starting with clinical samples in 1-2 days following a simple laboratory workflow. This method has been successfully used by several groups studying Zika virus evolution and is facilitating an understanding of the spread of the virus in the Americas.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 1,190
- FWCI
- 79.48
- Field percentile
- top 1%
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- An amplicon-based sequencing framework for accurately measuring intrahost virus diversity using PrimalSeq and iVar
N. D. Grubaugh, K. Gangavarapu, … K. G. Andersen·bioRxiv·Aug 5, 2018
- Detection of viral pathogens with multiplex Nanopore MinION sequencing: be careful with cross-talk
Yifei Xu, Kuiama S. Lewandowski, … Derrick W. Crook·Frontiers in MicrobiologyPeer-reviewed·Sep 19, 2018
- Genome sequencing of the Monkeypox virus 2022 outbreak with Amplicon-based Oxford Nanopore MinION sequencing
Annika Brinkmann, Katharina Pape, … Andreas Nitsche·bioRxiv·Oct 20, 2022
- Assessment of Metagenomic MinION and Illumina sequencing as an approach for the recovery of whole genome sequences of chikungunya and dengue viruses directly from clinical samples.
L. E. Kafetzopoulou, K. Efthymiadis, … S. T. Pullan·bioRxiv·Jun 25, 2018
- Rapid multiplex small DNA sequencing on the MinION nanopore sequencing platform
Shan Wei, Zachary R. Weiss, Zev Williams·G3 Genes Genomes GeneticsPeer-reviewed·Mar 15, 2018
- Rapid cost-effective viral genome sequencing by V-seq
Longhua Guo, James Boocock, … Yi A. Yin·bioRxiv·Aug 15, 2020