bioRxivNeurosciencePreprint
iGlu3Fast and iGlu3Slow, improved fluorescent reporters for detection of spontaneous glutamate activity in the brain
Oanh TraniD, Sara Bertelli, Holly J. Hughes, Laura Rocha Llabrés, Tom D. CarteriD, Andrew J.R. PlestediD, Katalin TörökiD
Abstract
The genetically-encoded fluorescent glutamate sensor, iGluSnFR3, characterised by a high dynamic range and rapid on-kinetics, is an attractive sensor for glutamate imaging in the central nervous system. However, kinetic variants with ultrafast or slow off-kinetics are needed to broaden the spectrum of applications from monitoring rapid synaptic glutamate transients to mesoscale imaging of brain activity. Here we report binding-site variant S72T (iGlu3Fast) optimised for reporting fast glutamate release at individual sites with a fluorescence dynamic range of 57 and a decay t1/2 of 2 ms in solution, [~]5-fold faster than iGluSnFR3. In contrast, variants D25A and D25R (termed iGlu3Slow1 and iGlu3Slow2, respectively) presented with slow off-kinetics (decay t1/2 43 ms and 30 ms, respectively, at 20{degrees}C), while retaining high dynamic ranges (48 and 65, respectively). These values were reduced when expressed in HEK293T cells, glutamate dissociation from iGlu3Fast slowed to a decay t1/2 of 6.9 ms, while decay t1/2-s of 115 and 234 ms were measured for iGlu3Slow1 and iGlu3Slow2, respectively. The slow decay rates in cells were in accordance with reduced Kd-s in the range of 200 M for iGlu3Fast and 6.4 and 8.4 M for iGlu3Slow1 and iGlu3Slow2, respectively. 2-photon imaging in organotypic hippocampal slices reported spontaneous activity with high sensitivity by both iGlu3Fast and iGlu3Slow2. Strikingly, different kinds of glutamate transient were detected by the fast- and slow-decay sensors indicating that the rapid kinetics and increased fluorescence dynamic range make iGlu3Fast an excellent candidate for imaging high-frequency glutamate release at synapses while iGlu3Slow2 has the potential for mesoscale imaging of brain activity to record global events with high sensitivity.
- Citations
- 0
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Stability, affinity and chromatic variants of the glutamate sensor iGluSnFR
Jonathan S. Marvin, Benjamin Scholl, … Loren L. Looger·Nature MethodsPeer-reviewed·Oct 19, 2018
- Glutamate indicators with improved activation kinetics and localization for imaging synaptic transmission
Abhi Aggarwal, Rui Liu, … Kaspar Podgorski·Nature MethodsPeer-reviewed·May 4, 2023
- Kinetic mechanisms of fast glutamate sensing by fluorescent protein probes
C. Coates, S. Kerruth, … K. Torok·Biophysical JournalPeer-reviewed·Jan 1, 2020
- Ultrafast glutamate sensors resolve high-frequency release at Schaffer collateral synapses
Nordine Helassa, Céline D. Dürst, … Katalin Török·Proceedings of the National Academy of SciencesPeer-reviewed·May 7, 2018
- Glutamate indicators with increased sensitivity and tailored deactivation rates
Abhi Aggarwal, Adrian Negrean, … Kaspar Podgorski·Nature MethodsPeer-reviewed·Dec 23, 2025